74
4.
lift the Feed Roller Assembly out of the compartment.
5.
Install the new Feed Roller Assembly.
1
Insert the long pin of Roller Assembly in the mounting hole of
the compartment that matches the Feed Roller number.
2
Push to engage the gear with the gear in the compartment, and
then rotate the plastic bushings up to lock it.
1
2
6.
close the feed path cover back into place, and then close the ADF
cover.
7.
click
i
(information) from the iDocScan touch panel, then click
Reset
next to the counter of Feed Roller 1 count and Feed Roller 2
count to set the counter back to “0”.
mAINteNANce
(cONtINUeD)
Summary of Contents for idocscan p45