Technical Data
User manual 55530_hdb_en_16
28 / 156
Derating
4.1.2
Environmental characteristics
Short circuit protection
High-side switch with
overload protection
Connection/female connector
M12
Conductor cross-section M12
≤0.75 mm
2
Output
Fig. 4-1: Derating DO output current
Fig. 4-2: Derating actuator supply total current
Climatic
Operating temperature
-25 °C ... +55 °C
Storage temperature
-25 °C ... +70 °C
provide acclimatization
for commissioning
Transport temperature
-25 °C ... +70 °C
provide acclimatization
for commissioning
Relative humidity
≤95 %
Installation height
Above sea level
≤2000 m
Mechanical
Vibration test
EN 60068 Parts 2-6
10 ... 58 Hz,
amplitude
0.35 mm,
58 ... 150 Hz; 20 g
Shock test
EN 60068 Parts 2-27
50 g, duration 11 ms
Electrical safety
Degree of protection
EN 60529
IP67
Protection class
When using an SELV or PELV power supply
III
Degree of pollution
2
Emitted EMC interference
Radio interference field strength of hous-
ing
EN 55016-2-3
Compliant
Interference voltage
EN 55016-1-2
Compliant