7 Condensed Message Definition
PDM Receive Messages
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
0
Output Channel
Soft-Start Step Size
Motor/Lamp Mode
Loss of Comm
FF
POR, Cmd, Braking
LSC, Response
Configure Outputs 1-6
6
Output 1 Config
Output 2 Config
Output 3 Config
Output 4 Config
Output 5 Config
Output 6 Config
FF
Configure Outputs 7-12
7
Output 7 Config
Output 8 Config
Output 9 Config
Output 10 Config
Output 11 Config
Output 12 Config
FF
Command Outputs 1-6
4
Output 1 Command
Output 2 Command
Output 3 Command
Output 4 Command
Output 5 Command
Output 6 Command
Outputs 1-6 Enable
Command Outputs 7-12
5
Output 7 Command
Output 8 Command
Output 9 Command
Output 10 Command
Output 11 Command
Output 12 Command
Outputs 7-12 Enable
PDM Transmit Messages
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Analog Inputs 1-2,
Digital Inputs
128
Digital Inputs 1-4
Digital Inputs 5-8
Digital Inputs 9-12
Analog Input 1 LSB
Analog Input 1 MSB
Analog Input 2 LSB
Analog Input 2 MSB
Analog Inputs 3-4,
Output Diagnostics
129
Outputs 1-4
Diagnostics
Outputs 5-8
Diagnostics
Outputs 9-12
Diagnostics
Analog Input 3 LSB
Analog Input 3 MSB
Analog Input 4 LSB
Analog Input 4 MSB
Analog Inputs 5-6,
Battery and Sensor Supply
130
Sensor Supply Status
Battery Voltage LSB
Battery Voltage MSB
Analog Input 5 LSB
Analog Input 5 MSB
Analog Input 6 LSB
Analog Input 6 MSB
Analog Inputs 7-8,
SW Version, Power Supply
131
Power Supply Status
Software Rev LSB
Software Rev MSB
Analog Input 7 LSB
Analog Input 7 MSB
Analog Input 8 LSB
Analog Input 8 MSB
Outputs 1-6 Feedback
132
Output 1 Feedback
Output 2 Feedback
Output 3 Feedback
Output 4 Feedback
Output 5 Feedback
Output 6 Feedback
FF
Outputs 7-12 Feedback
133
Output 7 Feedback
Output 8 Feedback
Output 9 Feedback
Output 10 Feedback
Output 11 Feedback
Output 12 Feedback
FF
Output Function Handshake
134
Output Channel
Soft-Start Step Size
Motor/Bulb Mode
Loss of CAN
Not Used
POR, Cmd, Braking
LSC, Response
Outputs 1-6 Config Handshake
135
Output 1 Config
Output 2 Config
Output 3 Config
Output 4 Config
Output 5 Config
Output 6 Config
FF
Outputs 7-12 Config Handshake
136
Output 7 Config
Output 8 Config
Output 9 Config
Output 10 Config
Output 11 Config
Output 12 Config
FF
Byte Name
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
POR, Command, Braking
POR Command
POR Enable
Command Type
Motor Braking
LSC, Response
LSC Digital Input #
Calibration Time
Response
Outputs 1-6 Enable
PDM Transmit Rate
Output 6 Enable
Output 5 Enable
Output 4 Enable
Output 3 Enable
Output 2 Enable
Output 1 Enable
Outputs 7-12 Enable
Reserved (Always 11)
Output 12 Enable
Output 11 Enable
Output 10 Enable
Output 9 Enable
Output 8 Enable
Output 7 Enable
Configuration CH X
Current Limit
Feedback Type
Automatic Reset
HS or H-Bridge
Digital Inputs 1-4
Digital Input 4
Digital Input 3
Digital Input 2
Digital Input 1
Digital Inputs 5-8
Digital Input 8
Digital Input 7
Digital Input 6
Digital Input 5
Digital Inputs 9-12
Digital Input 12
Digital Input 11
Digital Input 10
Digital Input 9
Diagnostic CH 1-4
Diagnostic Bits CH 1
Diagnostic Bits CH 2
Diagnostic Bits CH 3
Diagnostic Bits CH 4
Diagnostic CH 5-8
Diagnostic Bits CH 5
Diagnostic Bits CH 6
Diagnostic Bits CH 7
Diagnostic Bits CH 8
Diagnostic CH 9-12
Diagnostic Bits CH 9
Diagnostic Bits CH 10
Diagnostic Bits CH 11
Diagnostic Bits CH 12
Sensor Supply Status
Reserved (Always 111111)
Sensor Supply High
Sensor Supply Low
Power Supply Status
Reserved (Always 111111)
Power Supply Status
Total Current Status