background image

M-6797B page 1 of 4

Description

TATTLETALE

®

annunciators and Magnetic Switches are

the nerve centers that translate SWICHGAGE

®

contact

operations into decisions and operate the alarm or
shutdown device. They are the electrical load carrying
devices for the alarm or shutdown device. TATTLETALE

®

annunciators indicate which monitored function failed
leading to the alarm or shutdown whereas magnetic
switches do not. Magnetic switches operate basically as a
latching relay.

Application

Magnetic Switches and TATTLETALE

®

annunciators are

available for use with engines or electric motors. Various
circuits, time delays, and contact configurations are
available to match the power source and mode of
operation required for alarm only, alarm before shutdown
or shutdown only.

For distributor ignition engines, the magnetic switch opens
the distributor coil circuit to cause shutdown. For magneto
or CD ignitions the magnetic switch grounds the ignition
output. Some models can also trip fuel valves instead of
or in addition to grounding the ignition. Diesel engines are
shut down by either closing off the fuel or air supply.
Magnetic switches and TATTLETALE

®

annunciators can

make or break circuits for these engines.

For electric motor applications, various magnetic switches
are available to operate the motor starter, holding coil
directly or in conjunction with appropriate Murphy
Transformer-Relay assembly.

Features

Magnetic switches and TATTLETALE

®

annunciators

described in this bulletin are electrically tripped relay type
devices. Models are available to operate from battery
power, 120 VAC, conventional magnetos and capacitor
discharge type ignitions. Energized to run models allow
CLOSED LOOP circuitry. Others draw momentary power to
trip. Configurations are available for contact make or
contact break to cause shutdown. Some models have both
make and break contacts.

All models have a weather resistant case with screw
terminals for ease of customer hookup. Manually reset
models have a face mounted reset push button which also
serves as a fault indicator in the TATTLETALE

®

version. In

this application, one or more TATTLETALE

®

/magnetic

switches are used to advise operating personnel which
monitored function caused shutdown. Only the
TATTLETALE

®

connected to that function sensor trips

causing the reset push button to pop out.

Electrically reset models perform the same functions as
the manually reset models and are reset by cycling the
power supply off and then on.

Time delay models use reliable solid state timing circuits to
lockout operated switch contacts for start-up and/or to allow
operation of alarms before shutdown occurs. Specific
models allow application of power to a shutdown circuit and
automatic disconnect of power after a given time delay.

See the chart on page 2 for features by part number.

Nerve Centers 
for Murphy 
SWICHGAGE

®

Instruments and 
Automation 
Systems

* Applies to selected models.

*

M-6797B

Revised 10-06

Catalog Section 25

TATTLETALE

®

Annunciators and 

Magnetic Switches

Summary of Contents for M-6797B

Page 1: ...ly Features Magnetic switches and TATTLETALE annunciators described in this bulletin are electrically tripped relay type devices Models are available to operate from battery power 120 VAC conventional magnetos and capacitor discharge type ignitions Energized to run models allow CLOSED LOOP circuitry Others draw momentary power to trip Configurations are available for contact make or contact break ...

Page 2: ... 5 Time Delay Indicates operation of the time delay 6 Coil Resistances in OHMS or coil and resistor 1 0 5 2 18 3 30 4 72 5 90 190 for 12 24 6 288 7 339 678 for 12 24 8 339 618 for 12 24 Coil Voltage 12 volt 24 volt 12 24 volt 120 VAC Magneto ignition CD ignition Contacts see Note 2 below NCH NOH NCG NOG Coil see Note 6 below Latch Type Energize to trip Energize to latch Reset Type Manual indicatin...

Page 3: ...cts loss of magneto CD ignition output and transfers con tacts for customer use Contacts 10 amps 48 VAC VDC M42641CD transfers SPDT dry contacts when tripped 760A 760AF 761APH Use for distribu tor ignition or diesel Time delay lockout of SWICHGAGE contacts on start up only cus tomer wired for delayed or immediate trip on shutdown Breaks and makes circuits when tripped 760A resets automatically whe...

Page 4: ...ase model to indicate an inline fuse instead of a base mounted fuse Example 760AF 761APHF 117F 12 Volt negative ground version only Warranty A limited warranty on materials and workmanship is given with this FW Murphy product A copy of the warranty may be viewed or printed by going to www fwmurphy com support warranty htm Printed in U S A 07 8 793 CONTROL SYSTEMS SERVICES DIVISION P O Box 1819 Ros...