background image

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

ELECTRIC DRINKING FOUNTAIN

Date: 

04/20/2021

7020-998-001

 

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

 

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

 

 

 

 

Murdock warrants that every cooler, bottle filling station, packaged water chiller, fountain and accessory to be free 
from defects in material and workmanship under normal use for one (1) year from date of install or eighteen (18) 
months after the date of shipment from the factory, whichever comes first. 

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

LIMITED EXPORT WARRANTY - 

One year on parts only. 

Murdock warrants the compressor and hermetically sealed refrigeration system, including cooling coil assembly 
when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship 
under normal use for an additional four (4) years from the end of the one (1) year period described above.

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

LIMITED WARRANTY - UNITED STATES & CANADA

COMPLIES 

WITH

Member of

Murdock™ assumes no responsibility for use 
of void or superseded data. © Copyright 
Murdock Mfg., City of Industry, CA  Member of  
Morris Group International. Please visit 

www.murdockmfg.com

 

for most current 

specifications.

15125 Proctor Ave, City of Industry,

CA, 91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

www.murdockmfg.com

 

Federal
Public Law
111-380 
(No Lead)

04/20/2021

AR81.8 Series

 

(220V Compressor Only)

Test rating 
conditions are
compliant with 
ARI 1010.

Ligature Resistant, Barrier Free, Inverted, Fully Recessed Wall Mounted 

Electric Drinking Fountain

AR81408S-BF SHOWN

7020-998-001

Summary of Contents for AR81.8 Series

Page 1: ...th these instructions will constitute an abnormal use condition and void the warranty Stainless steel must be protected on job site during construction and must be properly maintained after the water has been introduced into the water cooler or drinking fountain or Murdock s limited warranty is void LIMITED EXPORT WARRANTY One year on parts only Murdock warrants the compressor and hermetically sea...

Page 2: ... I D I M E N S I O N S H O W N I S F O R RECOMMENDED ADULT HEIGHT ADJUST VERTICAL DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL STATE LOCAL CODES NOTES 29 737 C L 1 2 79 2019 6 1 2 1 9 AR81 8 SERIES ROUGHING IN AND DIMENSIONAL DRAWING 2 51 10 11 C L GENERAL NOTES 5 MOUNTING FRAME ASSEMBLY 3 VANDAL RESISTANT PUSHBUTTON ACTUATOR FOR BUBBLER 7 VENTILATION GRILL 6 8 0 GPH CHILLER 2 OPTIONAL BF LIGATU...

Page 3: ...o strainer or other components 1 Water Supply Service Stop Valve Water Connections and Electrical Connections to be supplied by others in accordance with local codes 1 Read all installation instructions carefully before proceeding 8 This unit must be grounded per the requirements of applicable electrical codes 5 It is common for electrical equipment to be grounded to water lines either within a st...

Page 4: ...n building water supply and check all connections for leaks 3 Insert and center mounting frame into the rough in blockout with sides top and bottom flange against finished wall Level and secure using mounting hardware provided by the installer Verify if level and shim if necessary 2 Air within the Fountain or the structure supply piping will cause an irregular outlet stream until purged out by inc...

Page 5: ...01 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of Frame Assembly Centered On Opening Fountain Assembly Mounting Tab Upper Removable Vented Access Cover See Details Chiller Unit Lower Removable Access Cover 17 179 53 1346 12 305 Wall Depth AR81 8 SERIES INSTALLATION 29 737 ...

Page 6: ...r cause water metal content to increase ROUGH IN GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES MM 2 ALLOW 4 INCHES 102MM MINIMUM CLEARANCE ON TOP AND FRONT FOR VENTILATION 3 IT IS RECOMMENDED THAT ALL WATER OUTLETS BE CONNECTED DIRECTLY AND NO MORE THAN 7 FEET AWAY FROM THE CHILLER FOR ANYTHING GREATER THAN 7 FEET CHILLED WATER MAY NOT BE EXPOSED UNTIL ALL WATER IN RISER HAS BEEN RELEASED ALL CHILL...

Page 7: ... Fax 626 855 4860 www murdockmfg com Member of IN OUT IN OUT 2 3 1 TO DRINKING FOUNTAIN 1 OUT IN 4 5 2 3 4 INSULATED 1 4 OD TUBING Y STRAINER PROVIDED ANGLE STOP BY OTHERS CHILLER w 3 8 OD TUBE INLET OUTLET CONNECTIONS OPTIONAL WF1 1500 GALLON WATER FILTER SHOWN WITH NOTE INSULATION TUBING MAY OVERLAP FITTINGS ILLUSTRATIONS MAY SHOW EXPOSED 1 4 OD TUBING FOR CLARITY ONLY 1 2 3 4 5 1 1 4 OD TUBE IN...

Page 8: ...tting Water test the connection assembly prior to leaving the site to ensure there are no leaks DISCONNECTING THE TUBE Prior to disconnecting the Tube from the Fitting ensure that the Water Line is depressurized Push Collet Square towards the Push In Fitting Body and hold While holding the Collet in pull on the PE Tubing to remove from the Push In Fitting TO CUT TUBE Cut to fit length of 1 4 PE Tu...

Page 9: ... 0 GPH CHILLER 3 7000 024 001 Y STRAINER ASSY W 1 4 NPT X 3 8 OD 4 7000 021 001 Y STRAINER ASSY W 1 4 NPT 5 0112 002 000 10 32 X 1 2 S S HEX C R BTN HD SCREW 6 7035 430 001 VENT PANEL RECESSED FOUNTAIN 7 7000 065 001 PUSH BUTTON W CARTRIDGE VALVE ASSEMBLY 8 7000 060 000 FLOW REGULATOR CARTRIDGE 0 5 GPM 9 7000 091 001 PUSHBUTTON W HEX ASSY 10 4854 020 001 DECK BUBBLER ASSY LR BPH 11 4854 030 001 NO...

Page 10: ...D CONNECTION 9 1895 708 000 1 4 OD PUSH IN ELBOW CONNECTION 2 7008 010 199 HOUSING 10 7008 012 199 FRONT PANEL 3 0124 031 000 8 3 8 HEX WASHER HD SLOTTED SCREW 11 7012 803 000 CAPACITOR 4 7008 015 001 CONDENSOR ASSEMBLY 12 7003 250 000 TEMPERATURE CONTROL 5 0332 013 000 1 OD x 7 16 ID FLAT WASHER 13 1895 121 000 1 4 OD PUSH IN CONNECTION 6 7012 150 000 3 32 x 1 5 8 HITCH PIN 14 7003 115 001 EVAPOR...

Reviews: