© Munters AB, 2020
200
26.7
Expansion Specifications
Parameter
Specifications
Input Power Voltage
115/230 VAC, 50/60 Hz
Input AC Power
0.2A
Maximum number of relays
operating simultaneously
10
Note:
Running relays at the above current levels provides between 50,000 – 100,000 switching
operations.
Communication
RS-485: 115 Kbps, 8 bit, even parity
Operating Temperature Range
-10° to +50° C (+14° to +125° F)
Storage Temperature Range
-20° to +80° C (-4° to +176° F)
Environmental Specifications
•
Altitude: -400 m to 2000 m
•
Relative Humidity: 20% - 90%
•
Main supply voltage fluctuation up to +10 - 20%
•
Overvoltage category II
Enclosure
•
Water and dust tight
•
Indoor use only
Dimensions (H/W/D)
403 x 324 x 141 mm/16 x 13 x 5.6 inches
Fuses
Fuse F2 on PS card: 3.15A, 250V
Certification
•
Disconnection device/overcurrent protection: In the building installation, use a certified 2-
pole circuit breaker rated 10A, certified in accordance with the IEC standard 60947-2 (in the
US and Canada use a Listed Brach Circuit protective circuit breaker). This step is required to
provide overcurrent protection and mains disconnection. The circuit breaker must be easily
accessible and marked as the controller disconnect device.
•
Main Supply Voltage: Permanently connect the controller to the mains in accordance with the
relevant national code. Provide fixed wiring inside a flexible conduit. Relays must be suitably
protected against overcurrent, using a circuit breaker rated at 10A.
26.8
Expansion Spare Parts
•
•
•
TRIO 20 Main Container Spare Parts
•
Summary of Contents for TRIO
Page 18: ... Munters AB 2020 18 Figure 5 Relay wiring detailed view Figure 6 Relay and port numbering ...
Page 86: ... Munters AB 2020 86 ...
Page 88: ... Munters AB 2020 88 4 Verify that each channel is enabled ...
Page 170: ... Munters AB 2020 170 Click to view the bird scale data ...
Page 180: ... Munters AB 2020 180 25 3 2TRIO 20 CONTAINER SPARE PARTS ...
Page 182: ... Munters AB 2020 182 25 3 3TRIO 20 DOOR CARD SPARE PARTS ...
Page 184: ... Munters AB 2020 184 25 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Page 196: ... Munters AB 2020 196 Figure 36 Relay and port numbering 26 2 3POWER Figure 37 Power ports ...