12.4.4
D
EFINING THE
W
IND
C
HILL
F
ACTOR
TRIO can take into account the tunnel wind speed. The effect of this speed is the wind chill factor. When
taken into account, the ventilation is adjusted to reflect the effective temperature according to a built-in
algorithm. The algorithm takes into account the wind velocity, house dimensions, and growth day. If there
is a humidity sensor installed, the algorithm also factor the relative humidity into the calculation (starting
from 40% RH). Factoring in the RH lowers the calculated wind chill factor.
•
Wind chill is activated in tunnel mode only.
•
Wind chill calculations take place between days 10 – 50.
Define the fan capacity (refer to Defining the Fans, page 56)
Define the house dimensions (refer to Defining the House Setting, page 97)
1. Go to System > Control Strategy > Ventilation. Scroll down to Wind Chill.
2. Define:
Summary of Contents for TRIO
Page 18: ... Munters AB 2020 18 Figure 5 Relay wiring detailed view Figure 6 Relay and port numbering ...
Page 86: ... Munters AB 2020 86 ...
Page 88: ... Munters AB 2020 88 4 Verify that each channel is enabled ...
Page 170: ... Munters AB 2020 170 Click to view the bird scale data ...
Page 180: ... Munters AB 2020 180 25 3 2TRIO 20 CONTAINER SPARE PARTS ...
Page 182: ... Munters AB 2020 182 25 3 3TRIO 20 DOOR CARD SPARE PARTS ...
Page 184: ... Munters AB 2020 184 25 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Page 196: ... Munters AB 2020 196 Figure 36 Relay and port numbering 26 2 3POWER Figure 37 Power ports ...