Timers
Timers provide an additional method of controlling relay devices, namely setting a timetable in which the
device can operate. In addition to the timetable, Trio enables setting up time cycles and temperature
ranges in which a device can operate.
Trio supports up to five timers.
Define at least one relay as a timer in Mapping Devices, page 48.
1. In Control > Timers, click edit, define a timer as Active.
2. Define for each timer:
o
Active House Mode: Define in which mode each timer can operate. Multiple modes can
be selected. Note: This option is not available for Central Exhaust or Central Corridor
setups.
o
Time: Timers can run 24 hours a day or in user-defined time frames. Define up to four
time frames for each timer.
o
Cycle: If enabled, define the cycle times. Range: 0 – 999 seconds.
o
Temperature: If enabled, define the temperature range in which the timers operate.
Range [-40° - +90°].
3. As an option, timers can be mapped to an outside temperature sensor. Go to System >
Temperature Definition.
Summary of Contents for Rotem Trio 20
Page 20: ... Munters AB 2020 20 Figure 6 Relay and port numbering ...
Page 44: ... Munters AB 2020 44 ...
Page 99: ... Munters AB 2020 99 Refer to Tunnel Ventilation page 123 for more details ...
Page 141: ... Munters AB 2020 141 If an outside temperature sensor is enabled map timers to it if required ...
Page 160: ... Munters AB 2020 160 23 3 2TRIO 20 CONTAINER SPARE PARTS ...
Page 162: ... Munters AB 2020 162 23 3 3TRIO 20 DOOR CARDS SPARE PARTS ...
Page 164: ... Munters AB 2020 164 23 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Page 186: ... Munters AB 2020 186 Figure 33 Relay and port numbering 26 2 3POWER Figure 34 Power ports ...
Page 199: ... Munters AB 2020 199 2 Insert and secure the SMA connector ...
Page 202: ... Munters AB 2020 202 example only ...