© Munters AB, 2018
20
Soft Minimum By Day
Day Min Cold Min Warm Max
1 1 11 25
14 3 13 30
98 9 19 30
Soft Minimum By Time
From Time Min Cold Min Warm Max
8:00 1 7 25
20:00 3 5 23
By Time
From Time Min Max
8:00 1 21
20:00 3 21
The Minimum/Maximum Level menu sets the current absolute minimum and maximum ventilation levels
available. You have 4 minimum maximum level choices:
•
Min/Max by Growth Day (1)
•
Min/Max by Time of Day (2)
•
Soft Min/Max by Day or Time (3 or 4)
The third option provides the following; in extreme cold weather the min level ventilation might be
decreased. For that, the user utilizes the Soft Min level that operates according to outside or inside
temperature.
For example:
•
Target temperature = 23.3°C
•
Growth day = 1
5.2.1
Soft Min Max Levels by Day levels
System parameters -> Min/Max
•
Level control
DSFT (Soft Min by days)
•
Soft Min temp
Out (Control by outside temperature)
•
Soft Min Band
2.2°C (Differential below heat temperature)
Day
Min Cold
Min Warm
Max
1
1
10
30
2
3
4