6.2
General Settings
This menu sets general weighing parameters.
NOTE:
Only Broiler/Layers Mode supports this function.
•
Bird Scale Mode: Select the weighing method:
o
SEXED: Considers all birds to be the same sex or ‘unisex’ as in mixed broilers. It
computes its own reference weight or acceptable range from the weighed birds.
o
MIXED: Considers the flock to be mixed males and females, with the goal of identifying
each bird weight as male or female, which is, classifying it according to a pre-
programmed pair of expected weight curves.
•
Uniformity Range (5-30%): Controller classifies bird weights within this percentage of the
average as uniform. Default is 10%.
•
Curve Selector (for mixed): There are three standard pairs of pre-programmed weight curves.
If you use the mixed weighing method, edit the curves to match your expected growth profile
(BROILER, TURKEY, or BREEDER).
•
Weigh During Feed Days: Allow weight data to be recorded on feed days. When set to NO,
this data is discarded. Default: No
6.2.1
G
ENERAL
S
ETTINGS
H
ELP
|
S
ET
D
EFINITIONS
While viewing the
General Settings
menu: Press
HELP
, select SET, and press
ENTER.
•
Factory Default Curve: Select YES to return bird curves to the factory default settings
GENERAL SETTINGS
Bird Scale Mode
Uniformity Range (5-30%)
Curve Selector (for mixed)
Weigh During Feed Days
SEXED
10
BROILER
NO
BIRD CURVE
Factory Default Curve
No
SEXED
MIXED
BROILER
TURKEY
BREEDER