DIP switch is located on the hydraulic module main control board (see "9.3.1 main control board of hydraulic module") and
allows configuration of additional heating source thermistor installation, the second inner backup heater installation, etc.
10.2.1 Function setting
10.2 DIP switch settings overview
T4H1
T4H2
T1SETH2
T1SETH1
T4
T1S (T1S2)
3.The automatic setting curve for heating mode
The automatic setting curve is the ninth curve,the ninth curve can be set as following:
State:In the setting the wired controller, if T4H2<T4H1, then exchange their value; if T1SETH1<T1SETH2, then exchange
their value.
T4
-10
≤
T4
<
15
15
≤
T4
<
22
22
≤
T4
<
30
30
≤
T4
1-T1S
16
11
8
5
2-T1S
17
12
9
6
3-T1S
18
13
10
7
4-T1S
19
14
11
8
5-T1S
20
15
12
9
6-T1S
21
16
13
10
7-T1S
22
17
14
11
8-T1S
23
18
15
12
T4
-10
≤
T4
<
15
15
≤
T4
<
22
22
≤
T4
<
30
30
≤
T4
1-T1S
20
18
17
16
2-T1S
21
19
18
17
3-T1S
22
20
19
17
4-T1S
23
21
19
18
5-T1S
24
21
20
18
6-T1S
24
22
20
19
7-T1S
25
22
21
19
8-T1S
25
23
21
20
4.The environment temperature curves of the low temperature setting for cooling mode
5.The environment temperature curves of the high temperature setting for cooling mode
T4C1
T4C2
T1SETC2
T1SETC1
T4
T1S (T1S2)
6.The automatic setting curve for cooling mode
The automatic setting curve is the ninth curve,the ninth curve can be set as following:
State:In the setting the wired controller, if T4C2<T4C1,then exchange their value; if T1SETC1<T1SETC2, then exchange
their value.