MUMU-BP Blood Pressure Monitor Manual V0.5

Page

1

Upper-arm Wireless Blood Pressure Monitor

User Manual

Type: MUMU-BP2 (Arm-type)

Thank you for choosing a MUMU product, Just in case that you are facing any problems
with your device, please contact us:
Xiamen Firstmed Medical Technology Co., LTD
East of 3rd Floor , No.4 Zhonghangji Building, No.1 Huli Avenue,Huli District, Xiamen
Service hotline: 400 999 2781
Service E-mail:[email protected]

www.mymumu.com

Summary of Contents for MUMU-BP2 Arm-type

Page 1: ...pe Thank you for choosing a MUMU product Just in case that you are facing any problems with your device please contact us Xiamen Firstmed Medical Technology Co LTD East of 3rd Floor No 4 Zhonghangji B...

Page 2: ...e monitor 13 2 Measuring method 2 1 Mobile software installation 15 2 2 Blood pressure measuring 16 2 3 Historical Data Display 19 2 4 Cloud Storage 20 2 5 Other Functions of Mobile Software 21 3 FAQ...

Page 3: ...stolic blood pressures and pulse rate frequently It is only designed for adults use and the range of the cuff circumference is 17cm 42cm 3 cuff sizes available please refer to the size you chose After...

Page 4: ...on manual and any other literature included in the box before using the unit Self judgment might possibly lead to exacerbation of diseases Diabetes hyperlipidemia and high blood pressure etc can exped...

Page 5: ...fe of the accessories The operator shall not touch the output of battery USB port when using As the product and armlet are not waterproofing please avoid rain sweat or water If the product is used clo...

Page 6: ...r be used on infants young children pregnant or pre eclamptic patients 2 Please do not share the cuff with any infectious person to avoid cross infection Caution The user is cautioned that changes or...

Page 7: ...pment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equip...

Page 8: ...CCOPANYING DOCUMENTS 2 Wireless communications equipment such as wireless home network device mobile phones coreless telephones and their base stations walkie talkies can affect this equipment and sho...

Page 9: ...BP Blood Pressure Monitor Manual V0 5 Page 9 1 2 Composition of product All products have been packaged Please open the packing cases and make sure whether they are complete MUMU BP2 USB Cable Storage...

Page 10: ...MUMU BP Blood Pressure Monitor Manual V0 5 Page 10 1 3 Name of components MUMU BP2...

Page 11: ...tooth indicator light Connection to external power Non connection to external power Power off off Waiting to connect to cell phone Blue light flashing Connected to cell phone Blue light on Charging po...

Page 12: ...battery by inadequately trained personnel which could result in a hazard such as a fire or explosion 4 If the AC adapter is abnormal please change the adapter 5 The monitor cable battery and cuff must...

Page 13: ...MUMU BP Blood Pressure Monitor Manual V0 5 Page 13 1 4 Application method of blood pressure monitor...

Page 14: ...MUMU BP Blood Pressure Monitor Manual V0 5 Page 14...

Page 15: ...0 5 Page 15 2 1 Mobile Software Installation MUMU software application has versions both for Android and iOS systems Users can install via the methods below Download http www mymumu com index php Down...

Page 16: ...ess raises blood pressure Avoid taking measurements during stressful times 3 The cuff can be applied to your left or right arm Always measure your blood pressure on the same Arm 4 Measurements should...

Page 17: ...ological characteristics Preparation MUMU software application connects to MUMU BP monitor via Bluetooth iPhones need to support Bluetooth LE 4 0 and Android phones need to support Bluetooth 2 1 Switc...

Page 18: ...start measuring the blood pressure Measurement can be done repeatedly If every other measurement interval is over ten minutes the monitor should be rebooted Turn off the Unit Press the power button fo...

Page 19: ...Save the measurement results after measuring the blood pressure You can view the historical data in the data window with a simple and clear graph Click the button of summary on the left upper corner a...

Page 20: ...ressure Monitor Manual V0 5 Page 20 2 4 Cloud Storage In the settings you can log on by family account and the measurement data can be uploaded to the cloud and realize data sharing both on computers...

Page 21: ...e measurement Smart reminders You can set reminders for measurement Advise to set at 6 9am and 16 18pm Cloud storage Upload the data via Bluetooth Permanent storage is in the unlimited cloud Multi use...

Page 22: ...desk or platform is too high it will result in the position of armlet higher than heart and the measurement results will be lower Q Why the measurement result at home is higher than that in hospital A...

Page 23: ...ment after even ten seconds will have a different result In order to manage the blood pressure correctly please measure at the same period every day A Blood pressure will fluctuate because of various...

Page 24: ...d pressure A The best time is 6 9am or 16 18pm If measuring in the morning please measure within one hour after getting up and after urinating and before the breakfast if taking hypotensor before it I...

Page 25: ...pressure classification in the graph below It s measured in the hospital of the upper arm and different ages There s no definition of low blood pressure But normally we think people whose high pressu...

Page 26: ...f Switch on blue light flashing and open the software to connect If it is iPhone the hardware is possible too old Support iPhone 4S and later phones and iPads Abnormal measurement result of blood pres...

Page 27: ...y The results are higher or lower than that measured in hospital Different results every time Refer to Q A Other cases Reboot and retest If it still doesn t work contact the seller Few customers canno...

Page 28: ...tor please use dry soft cloth after wringing out the water or neutral solvent as much as possible Storage suggestions Do not store the monitor in the places listed below Locations with easy contact to...

Page 29: ...3 7V 760mAh Polymer rechargeable battery Automatic power off Power shutoff automatically after the Bluetooth has disconnected for 2min Charging Power 5V 1 0A Operating condition 5 to 40 30 to 85 RH no...

Page 30: ...en cleaning the product enclosure and cuff do not use hard objects or aerosol cleaners please use the clean cloth to clean 3 Clean the product and cuff every week or every two weeks based on the opera...

Page 31: ...omanometers Part 3 Supplementary requirements for electro mechanical blood pressure measuring system EN1060 4 Non invasive sphygmomanometers Part 4 Test procedures to determine the overall system accu...

Page 32: ...tteries All warranty claims must be directed to the distributor responsible for the sale of the device The content of this warranty is subject to change without further notice 3 Periodical check Sensi...

Page 33: ...eclaration electromagnetic immunity Guidance and manufacturer s declaration electromagnetic immunity The BLOOD PRESSURE MONITOR is intended for use in the electromagnetic environment specified below T...

Page 34: ...ower frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment NOTE UT is the a c mains voltage prior to application of the tes...

Page 35: ...ue to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the BLOOD PRESSURE MONITOR is used exceeds the applicable RF com...

Page 36: ...s rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the m...