![Multiva FX300 Comfort Operation And Maintenance Manual Download Page 122](http://html1.mh-extra.com/html/multiva/fx300-comfort/fx300-comfort_operation-and-maintenance-manual_1856368122.webp)
7.1.2.4. Checking the tightness of coulter bolts
Figure. 7.1.2.4. - 149. Coulter shank bolts
1. Check that the coulter shank M20 bolts (1) are tight.
There are 12 coulter shank bolts on the FX300 and 18 on the FX400.
If needed, tighten the bolts to torque 300 Nm.
Figure. 7.1.2.4. - 150. Bolts of the coulter covering wheel and depth adjustment
2. Check that the 2 M16 (3) and M20 (4) bolts on all the coulter covering wheels are tight.
Tighten the bolts, if needed.
3. Check that the M16 (1) and M12 (2) coulter depth adjustment bolts are tight.
Tighten the bolts, if needed. The tightening torque is 120 Nm for the M12 bolt (2).
Operation and maintenance manual
FX300 and FX400 Comfort
1.00
122 (189)
Summary of Contents for FX300 Comfort
Page 181: ...Hydraulic schematics FX300 and FX400 1 Hydraulic schematics FX300...
Page 182: ...Hydraulic schematics FX300 and FX400 2...
Page 183: ...Hydraulic schematics FX300 and FX400 3 Hydraulic schematics FX400...
Page 184: ...Hydraulic schematics FX300 and FX400 4...
Page 185: ...Electrical schematics FX300 and FX400 Comfort 1 Electrical schematics...
Page 186: ...Electrical schematics FX300 and FX400 Comfort 2...
Page 187: ...Electrical schematics FX300 and FX400 Comfort 3...