Figure. 6.18. - 143. Cylinder stoppers
4. Place the 4 cylinder stoppers (4) on the cylinder rod so that the coulters are slightly raised
off of the ground.
The FX300 has 1 lifting cylinder (2) onto which the stoppers are placed. The
FX400 has 3 lifting cylinders (1 -3). The stoppers are placed on the outermost
cylinders (1, 3).
5. Depressurise the coulter pressure circuit by holding the tractor valve open for approx. 10
seconds.
The coulter pressure status is displayed on the coulter pressure gauge (see
section 4.2.1.7. Coulter pressure gauge).
6. Use wheel wedges or blocks to prevent the machine from moving during long-term
storage.
Operation and maintenance manual
FX300 and FX400 Comfort
1.00
116 (189)