Page 1: ...1 DIP40 IP INTERCOM DOORPHONE USER MANUAL It obeys the rules of AEEE regulations Multitek...
Page 2: ...OM DOORPHONE HAS WARRANTY FOR 2 YEARS AGAINST MANUFACTURING DEFECTS Multitek has rights to change the features of the device given in this document prior given any information Manufacturer Importer Mu...
Page 3: ...o Enter Door Password Open the Door 13 3 2 4 Remove Door Opening Passwords 13 3 2 5 Using Keypad Buttons to Call the Rooms 14 3 2 6 Opening the Door During Ringing or Conversation of a Room with the D...
Page 4: ...OXIMITY FEATURE TO OPEN THE DOOR 37 6 DESIGNING PHONEBOOK ON COMPUTER AND TRANSFERRING TO THE DOORPANEL 38 7 UPDATING DIP40 DOORPANEL SOFTWARE 39 8 USING OF DIP40 DOORPANEL 40 8 1 USING DIP40 AS SITE...
Page 5: ...periodic maintenance For maintenance and repair please consult to the authorized services By rubbing with dry cloth you can clean the product periodically You can keep the product in its case when you...
Page 6: ...ble to seven colors Door Release Password proximity NFC card Operating Temperature 20 55 c heating pad for lower temperature Humidity 20 95 non condensed Installation Flash mount or surface mounth wit...
Page 7: ...7 2 2 Appearance PROXIMITY MIFARE READER SPEAKER CAMERA NIGHT VISION LEDS TOUCH FUNCTION BUTTONS 4 pcs 4 TFT LCD SCREEN TOUCH KEY PAD LIGHT SENSOR MICROPHONE Multitek...
Page 8: ...ion cables Use RJ45 cable to connect the device to the network Place DIP40 to the wall mount aparatus by using 4 pieces holding tins Use 4 pieces 2 9mmx13mm screws given in the giftbox to fix DIP40 an...
Page 9: ...9 2 2 2 Back Side of DIP40 DOOR OPENER CONTACTS ETHERNET CAMERA ANGLE ADJUSTMENT LED FRAME CONNECTION...
Page 10: ...the proper position tight the screw to place the camera 2 2 4 Network Connection Connect CAT6 cable coming from PoE switch to Ethernet socket This cable enables power of the device and network connect...
Page 11: ...ture The screen shows the name of the apartment its number and the block number 01 Main Screen The main screen shows the function of the buttons The explanations are put on the side of the buttons as...
Page 12: ...ers and their inhabitants recorded to the device The left side buttons scroll the lines one line up or down The right side buttons scroll the lines one page up or down The line selected will be shown...
Page 13: ...of the following pages is shown If the valid password is entered the door release function of the doorpanel works and the door is opened The duration of the door release time is programable 3 2 4 Remo...
Page 14: ...of the panel The only rooms belonged to the block where the doorpanel is placed may be callable Therefore to call a room the user enters just the room number without block number The block number of...
Page 15: ...ite numbers block 99 3 2 6 Opening the Door During Ringing or Conversation of a Room with the Door Panel When a room inside of a block is called from the doorpanel the room may open the door by touchi...
Page 16: ...ystem device connection parameters SYSTEM PASSWORD is needed HOME Lower left button to return to the Welcome Page PARAMETERS Lower right button to programm device related parameters BLOCK PASSWORD is...
Page 17: ...some other program For example 005 as room number is entered below When the three digit room number is entered the corresponding name appears on the screen if there is any For example when 005 is ente...
Page 18: ...pears After erasing the complete phonebook the new phonebook may be loaded with SD card or by a computer using Technical Maintenance Program 4 1 1 3 Send Phone book To send other doors in the same blo...
Page 19: ...s on the message area If it is not edited the message appears as NOT DEFINED If it is blank edited you see a blank line instead of a name To edit the name of the room the user touches the keypad digit...
Page 20: ...following touches are done and the message appears as ENTER ROOM NUMBER AND PRESS OK The user enters the room number of the room whose proximity card will be assigned and makes The message shown will...
Page 21: ...e CARD RECORDED The next page becomes asking DO YOU WANT TO RECORD ANOTHER CARD Note that it is possible to record up to 5 proximity cards to a room Please see the following pages If the proximity car...
Page 22: ...card icon Then the number of the security to be routed IS entered and confirmed 4 1 2 4 Delete Proximity Card s This feature is used to delete ALL proximity cards assigned to a room To delete all prox...
Page 23: ...creens If CANCEL is touched the previous page appears as following pages 4 3 1 Block Setup This programming is used to enter the name number of the apartment for the welcome page of the doorpanel This...
Page 24: ...t name number and block door number by entering the program 4 1 3 1 Building Name No When APT NAME NO icon is touched the following pages appears with the message ENTER THE APARTMENT NUMBER AND PRESS...
Page 25: ...e is shown 4 1 3 2 Door Block No When DOOR BLOCK NO is touched the message ENTER THE DOOR BLOCK NO AND PRESS OK is seen The user enters the door or block number and and then makes SAVE The following p...
Page 26: ...d make When you entered the NEW password and make you see the new message as RE ENTER THE NEW PASSWORD AND PRESS OK You re enter the new password for example 7447 and make The new massege appears as T...
Page 27: ...ng the door camera type and DELETE ALL DOOR OPENING PASSWORDS When you touch the lower right button to select PARAMETERS page the devices ask the password as ENTER BLOCK PASSWORD The programmer enters...
Page 28: ...he related buttons The following page shows three selected colors The selected touch colors are thicked on the small boxes When the color is changed the result is immediatelly seen on the frame colors...
Page 29: ...on of the panel The duration as default is 1sec When DOOR RELEASE DURATION button is touched the next page comes with the message DOOR RELEASE DURATION XX ENTER AND PRESS OK The door release duration...
Page 30: ...assword Operations In this section the DOOR PASSWORD OPERAT ONS button is pressed 4 2 5 1 Removing Door Password This section is described in detail in section 3 2 4 Removing Door Opening passwords 4...
Page 31: ...ser selects PARAMETERS enters password and selects NEXT PAGE CAMERA and DATE TIME settings page appears HHM ARE YOU SURE TO DELETE ALL PASSWORDS TO THE ROOM ARE YOU SURE TO DELETE ALL PASSWORDS TO THE...
Page 32: ...AL CAMERA screen appears If INTERNAL CAMERA ise selected embedded doorpanel camera image is sent to room monitors If IP CAMERA ise selected external IP camera image is sent to room monitors Note Catal...
Page 33: ...e shows the following information Block no XX default 01 Door no XX default 01 Door release duration xx default 01 4 3 2 Ip Change Import Parameters Change This section enables to programm the BLOCK N...
Page 34: ...the door panel the SAVE button is touched If it is not saved please use CANCEL 4 3 3 Diagnostic and System Password Setup This section is used to make some diagnostic tests of the door panel and to ch...
Page 35: ...ou enter the new password for example 7447 and press When you entered the NEW password and make you see the new message as RE ENTER THE NEW PASSWORD AND PRESS OK You re enter the new password for exam...
Page 36: ...ord from his own indoor device by scrolling SETTINGS GENERAL SETTINGS DOOR PASSWORD Only non consecutive i e 1234 and non recurrent i e 1111 four digit password is accepted This password is set to all...
Page 37: ...on 5 2 USING PROXIMITY FEATURE TO OPEN THE DOOR The DOOR PANEL has a proximity card reader inside serving up to 200 rooms and up to 5 proximity cards can be assigned to each room To assign or delet pr...
Page 38: ...ages During Turkish phone book file creation create DIP40_phonebook_tr named file on Wordpad and SAVE AS with ENCODING type UTF 8 instead of ANSII Phone book can be uploaded to DIP40 door panel in two...
Page 39: ...ation file apk is provided by Multitek with a micro SD card Back lid of the door panel is opened SD card is inserted A USD mouse is connected to the USD socket CLR OK 99 is typed on the door panel Mai...
Page 40: ...t a SITE DOOR PANEL Door panel number 981 represents the initial door panel number 989 the 9th door panel Note 3 SITE DOOR PANEL catalogue number 99 981 1st SITE DOOR PANEL IP NO 10 99 29 1 99 982 2nd...
Page 41: ...lock 1 Door 1 is used as a master to transmit the timing data to all others In case of a power outage real time of Block 1 Door 1 keeps working and then power comes back It sends the real time informa...