Multitech MultiDSU56K Owner'S Manual Download Page 1

Multi

DSU

56K

TM

Rack Mount Multi-Rate DSU

Model MT56DSU-R

Owner's  Manual

82023101.p65

2/12/01, 2:52 PM

1

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for MultiDSU56K

Page 1: ...MultiDSU56K TM Rack Mount Multi Rate DSU Model MT56DSU R Owner s Manual 82023101 p65 2 12 01 2 52 PM 1 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...and to make changes from time to time in the content hereof without obligation of Multi Tech Systems Inc to notify any person or organization of such revisions or changes Record of Revisions Revision...

Page 3: ...Settings 16 2 2 1 12 Position DIP Switch 1 12 17 2 2 2 4 Position DIP Switch 13 16 17 2 2 3 RS232 V 35 Shunt 17 2 3 Changing the Default DIP Switch Settings 18 2 4 Installation Procedure 20 Chapter 3...

Page 4: ...4 4 2 9 TM Indicator 34 4 2 10 OOS Indicator 34 4 3 Diagnostic Tests 35 4 3 1 Local Loopback Test 35 4 3 2 Digital Loopback Test 36 4 3 3 Digital Loopback With Test Pattern Test 37 4 3 4 Test Pattern...

Page 5: ...MultiDSU56K TM Chapter 1 Introduction and Description 82023101 p65 2 12 01 2 52 PM 5 All manuals and user guides at all guides com...

Page 6: ...low Chapter 1 Introduction and Description contains an introduction to the MT56DSU R product and its features and functions Chapter 2 Hardware Installation provides configuration and installation proc...

Page 7: ...vides all of the functions required on the customer side of the network The MT56DSU R provides user selection of synchronous data communications at rates of 2400 4800 9600 19200 and 56000 bps and asyn...

Page 8: ...R contains the functions of a Data Service Unit DSU and a Channel Service Unit CSU in a single package 1 4 1 DSU Functions The DSU encodes data as pulses on the communications line by converting the...

Page 9: ...ATAPHONE Digital Data Service DDS or compatible network selectable sync speeds of 2400 4800 9600 19200 and 56000 bps selectable async speeds of 2400 4800 9600 and 19200 bps point to point and multipoi...

Page 10: ...y the total REN s contact the telephone company to determine the maximum REN for the calling area 4 If this equipment causes harm to the telephone network the telephone company will notify you in adva...

Page 11: ...ntact the state public utility commission public service commission or corporation commission for information Manufacture Multi Tech Systems Inc Model number MT56DSU R FCC Registration No AU7USA 18883...

Page 12: ...Pubs 62310 and 41450 FIC Codes 04DU5 24 2 4 Kbps digital interface 04DU5 48 4 8 Kbps digital interface 04DU5 96 9 6 Kbps digital interface 04DU5 19 19 2 Kbps digital interface 04DU5 56 56 Kbps digital...

Page 13: ...n 13 Input Impedance 135 ohms Delay Times in msecs RTS CTS DCD on DCD off 2400 8 1 7 5 7 0 4800 4 3 2 6 3 5 9600 2 2 1 6 1 5 19200 1 0 8 0 7 56000 0 4 0 3 0 2 82023101 p65 2 12 01 2 52 PM 13 All manua...

Page 14: ...MT56DSU R Owner s Manual 14 82023101 p65 2 12 01 2 52 PM 14 All manuals and user guides at all guides com...

Page 15: ...MultiDSU56K TM Chapter 2 Hardware Installation 82023101 p65 2 12 01 2 52 PM 15 All manuals and user guides at all guides com...

Page 16: ...cated behind the LEDs on the front of the board Each individual switch is numbered and can be in either the up OPEN or down CLOSED position The MT56DSU R is shipped from the factory with the configura...

Page 17: ...re and Anti Streaming options The defaults are 10 Bit Async Word Length Elastic Store disabled and Anti Streaming disabled If changes to these settings are required refer to section 2 3 2 2 3 RS232 V...

Page 18: ...2 1 The factory default settings are indicated by an in the Table 2 1 Table 2 1 MT56DSU R Switch Settings Switch Description Data Rate in bps 2400 4800 9600 19 2K 56K 1 Down Down Down Down Up 2 Down...

Page 19: ...Options 11 Up Circuit Assurance disabled Down Circuit Assurance enabled 12 Up System Status disabled Down System Status enabled Async Word Length 9 Bit 10 Bit 11 Bit 13 Up Down Up 14 Down Up Up Elasti...

Page 20: ...MT56DSU R is being connected to a V 35 interface place the 16 pin shunt in the V 35 position 3 Determine which slot the MT56DSU R board is going to be placed in the rack Apply the DSU LED sticker to...

Page 21: ...r cable information Refer to the Rack Mounted Modems Owner s manual for cable connections on the rack 8 To connect the phone line to the MT56DSU R using the phone cable supplied by Multi Tech connect...

Page 22: ...MT56DSU R Owner s Manual 22 82023101 p65 2 12 01 2 52 PM 22 All manuals and user guides at all guides com...

Page 23: ...MultiDSU56K TM Chapter 3 Operation 82023101 p65 2 12 01 2 52 PM 23 All manuals and user guides at all guides com...

Page 24: ...options when shipped from the factory Chapter 2 of this manual covers the changing of these option DIP switches Chapter 4 covers the Normal Diagnostic switch function The following sections describe...

Page 25: ...DIP switch settings 3 2 4 Elastic Store This function allows the MT56DSU R to compensate for small timing phase drifts that occur in applications using analog modems for off net non DDS extensions An...

Page 26: ...as a communications channel failure Refer to Chapter 2 for changing the default DIP switch settings 3 2 6 Circuit Assurance This option when enabled causes the MT56DSU R to condition the CTS signal t...

Page 27: ...for changing the default DIP switch settings 3 2 8 RTS Forced On With this option enabled the MT56DSU R provides a continuous CTS signal disregarding the state of the RTS signal at the DTE interface...

Page 28: ...2 for changing the default DIP switch settings 3 2 10 Async Word Length This option allows you to select the word length to be used by the MT56DSU R for asynchronous data transmissions The Async Word...

Page 29: ...wer requirements of Bellcore Pub 41028 data sets used on LADC when used at subrate speeds less than or equal to 19200 bps The MT56DSU R does not meet this requirement at the 56K bps rate The 56K bps r...

Page 30: ...R may be set for External Timing and the other set for DDS Timing however in this application the clock timing being supplied must be accurate to 0 008 of the enabled data transmission rate The Elast...

Page 31: ...MultiDSU56K TM Chapter 4 Troubleshooting 82023101 p65 2 12 01 2 52 PM 31 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 32: ...two or three letter overlay describing its meaning During normal operation the LEDs light flash or continuously lit to indicate the operating status During test mode the LEDs light during Test Patter...

Page 33: ...the remote sends an idle code to the local DSU 4 2 4 56K Indicator The 56K LED lights when the Data Rate selection is set at 56000 bps This indicator will be off for all other data rates Refer to Chap...

Page 34: ...st Mode LED lights when one of the Test switches is set to the down Test enabled position When the TM LED is lit normal operation network transmit receive cannot occur Refer to the Diagnostic Tests se...

Page 35: ...transmitting equipment If the remote equipment is transmitting properly contact your telephone company If the telco is required to perform remote tests the channel will be temporarily interrupted and...

Page 36: ...perform the Digital Loopback Test 1 Set DIP switch 9 on the remote MT56DSU R to the down position 2 The Test TM LED lights and if you send data from the local DTE it should be looped back to the local...

Page 37: ...detects a pre defined 15 bit pseudo random test pattern When an error is detected by the MT56DSU R the NS No Signal LED flashs 1 Set DIP switch 9 on the remote MT56DSU R to the down position 2 Set DI...

Page 38: ...an error is detected by the MT56DSU R the NS No Signal LED flashs To enable the Test Pattern Test perform the following 1 Set the DIP switch 10 on both the local and remote MT56DSU R boards to the dow...

Page 39: ...Loopback cable CADSURLB from Multi Tech or assemble one Refer to Appendix B for instructions on building the Loopback cable 2 Plug the Loopback cable into the DB9 connector on the DSU being tested 3...

Page 40: ...ne Refer to Appendix B for instructions on building the Back to Back cable 2 On the good DSU board set DIP switch 9 to the down position 3 Set one DSU to internal clocking and the other DSU to DDS clo...

Page 41: ...MultiDSU56K TM Chapter 5 Warranty Service and Tech Support 82023101 p65 2 12 01 2 52 PM 41 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 42: ...proof of purchase is not provided two years from date of shipment MTS MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITYAND FITNESS FOR A PARTICULAR PURPOSE ARE...

Page 43: ...phone number for the Multi Tech BBS is 1 800 392 2432 in the U S and Canada and for Worldwide calls 612 785 9875 The BBS can be accessed by any asynchronous modem operating at transmission speeds of...

Page 44: ...MT56DSU R Owner s Manual 44 82023101 p65 2 12 01 2 52 PM 44 All manuals and user guides at all guides com...

Page 45: ...MultiDSU56K TM Appendixes 82023101 p65 2 12 01 2 52 PM 45 All manuals and user guides at all guides com...

Page 46: ...application and Analog Off Net Extension application DDS Point To Point Application In this application the MT56DSU R provides the interface between the DDS line and the DTE at your site Your network...

Page 47: ...RTS controlled by the DTE Multi point DDS provides communication between a control station and two or more remote stations All data transmitted by the control station is sent to each remote station Fo...

Page 48: ...External Clocking Application This application is similar to theLocal Area Data Set application except for the timing option setting In the example below the DTE connector of the T1 mux is connected t...

Page 49: ...analog modems and lines to complete DDS circuits in an area where DDS is not available Site 3 in the example below or where the customer requires an extension of the DDS circuit for a special applica...

Page 50: ...T56DSU R to the DDS Network The DB9S connector has the following pinout configuration PINIDENTIFICATION Pin Description Destination 1 Transmit Pair To Line 2 N C 3 Transmit Pair To Line 4 Receive Pair...

Page 51: ...Element Timing As viewed from the rear DESCRIPTION This connector ties the MT56DSU R to the DTE The DB25S connector has the following pinout configuration PINIDENTIFICATION Pin Description Signal 2 Tr...

Page 52: ...DSU56 R is configured for V 35 DTE interface You can order the V 35 Interface Adapter cable CADSUR35 from Multi Tech This cable uses a 25 pin male connector at one end and a 34 pin Winchester female c...

Page 53: ...trip cable insulation 3 4 2 Strip wires 1 3 4 and 8 on one end of cable and 1 2 7 and 8 on other end a 1 4 3 Cut unstriped wires off 4 Solder wire 1 on one connector to 1 on the other 5 Solder wire 3...

Page 54: ...ginal signal sent You can order this cable CADSURLB from Multi Tech or build one using the instructions below Refer to Chapter 4 for test procedures SCHEMATIC BUILDINSTRUCTIONS 1 Strip cable insulatio...

Page 55: ...i Tech CADSURBB or build one using the instructions below Refer to Chapter 4 for test procedures SCHEMATIC BUILDINSTRUCTIONS 1 Strip cable insulation 3 4 3 Strip wires 1and 3 on one end of cable and 4...

Page 56: ...MT56DSU R Owner s Manual 56 82023101 p65 2 12 01 2 52 PM 56 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 57: ...MultiDSU56K TM Glossary 82023101 p65 2 12 01 2 52 PM 57 All manuals and user guides at all guides com...

Page 58: ...a communications line bps bits per second unit of measure for data transmission C Central Office CO the telephone company site where switching equipment is located as opposed to customer premises Chan...

Page 59: ...hone Digital Service AT Ts private line end to end digital service with data rates typically at 2400 4800 9600 19200 and 56000 bps Now an AT T Accunet family offering The DDS is a synchronous network...

Page 60: ...LED Light Emitting Diode a light source that emits visible light Local loopback a type of diagnostic test where the transmitted signal is returned to the sending device after passing through a local c...

Page 61: ...cates with the master station via the OCU All remote stations on the DDS must operate at the same bit rate AKA outlying station RJ Registered Jack a connector for use at customer site e g RJ11 RJ45 RJ...

Page 62: ...sending detecting and checking a pre defined pattern of bits Two wire circuit A circuit in which one channel line is used for communications in both directions Contrast four wire circuit 82023101 p65...

Page 63: ...Glossary 63 82023101 p65 2 12 01 2 52 PM 63 All manuals and user guides at all guides com...

Page 64: ...82023101 82023101 p65 2 12 01 2 52 PM 64 All manuals and user guides at all guides com...