USB Cable Recommendations

If your device has a USB connector, to avoid enumeration or power issues:

Use a high-speed USB cable that is as short as possible.

Use a well-shielded cable with at least 24 AWG wire pair for power/ground and 28 AWG wire pair for data
lines.

If possible, use a USB port that connects directly to the motherboard rather than a USB port with added
cabling inside the computer chassis.

Use USB 3.0 ports if available. These ports are typically rated for more current.

You can order the USB cable through MultiTech. The part number is CA-USB-A-MINI-B-3

Powering Down Your Device

CAUTION:

Failing to properly power down the device before removing power may corrupt your device's file

system.

To properly power down your device, use the following sequence :

1.

Issue the AT#SHDN command.

2.

Wait 30 seconds.

3.

Power off or disconnect power.

Mounting Device to Flat Surface

1.

Locate the groove on the bottom of the device.

2.

Slide the mounting bracket through the groove.

3.

To secure the bracket to the desired surface, place and tighten two screws in the holes on either end of
the mounting bracket. The dimensions illustration in this guide shows the mounting bracket, as well as
the dimensions for placement of the screws.

Summary of Contents for MultiConnect Cell MTC-G3

Page 1: ...MultiConnect Cell MTC G3 User Guide...

Page 2: ...control or aircraft navigation or communications systems control equipment for nuclear facilities or missile nuclear biological or chemical weapons or other military applications Restricted Applicatio...

Page 3: ...arers 14 Hazardous Locations Warnings 15 Class I Division 2 Groups A B C and D Hazardous Locations US and Canada 15 Avertissements relatifs l installation et aux emplacements dangereux 15 ATEX Europe...

Page 4: ...UDP Client to Connect to UDP Server 28 Configuring Device as UDP Listener to Accept UDP Client Connections 29 Transferring FTP File to FTP Server 30 Downloading File from FTP Server 31 Reading Writin...

Page 5: ...ilable with RS 232 or USB connectors Serial USB Documentation The following documentation is available on the Multi Tech Installation Resources website at www multitech com setup product go Document D...

Page 6: ...indicates connection to terminal emulation When not lit indicates no terminal is present for serial only CD Carrier Detect Indicates established data connection when lit for serial only LS Link Status...

Page 7: ...de 7 Side Panels The device has connectors on either side The figures that follow show the side panels Serial USB Note The power saving switch which appears with the NORMAL and LOW POWER labels is inc...

Page 8: ...Cellular Female SMA RS 232 DE9 USB Mini B USB 2 0 high speed or better Power 2 5 mm miniature screw on RS 232 models Power Requirements Voltage1 Serial 5 V to 32 V DC USB 5 V Physical Description Dim...

Page 9: ...end to voltages outside certified range and has not been evaluated by UL for operating voltages beyond tested range 2 Device has been tested up to 85 C UL Recognized 40 C limited by AC power supply UL...

Page 10: ...all box connection no data amps Average measured current amps at maximum power TX Pulse AVG Amplitude Current amps Total inrush charge measured in MilliCoulombs mC GSM850Mhz 0 040 0 238 1 14 18 56 Ser...

Page 11: ...PRODUCT OVERVIEW MultiConnect Cell MTC G3 User Guide 11 Dimensions Serial...

Page 12: ...PRODUCT OVERVIEW 12 MultiConnect Cell MTC G3 User Guide USB...

Page 13: ...provider To install the SIM card 1 Locate the SIM card slot on the side of the modem The slot is labeled SIM 2 Slide the SIM card into the SIM card slot with the contact side facing down as shown Whe...

Page 14: ...l Devices Potential interference Radio frequency energy RF from cellular devices can interact with some electronic devices This is electromagnetic interference EMI The FDA helped develop a detailed te...

Page 15: ...54 Ce type de boitier fournira uniquement un acc s au modem gr ce une cl ou un outils sp cifique 2 CET QUIPEMENT EST ADAPT EXCLUSIVEMENT POUR UNE UTILISATION EN ZONE DE CLASSE I DIVISION 2 GROUPES A B...

Page 16: ...er supply Antenna The antenna intended for use with this unit meets the requirements for mobile operating configurations and for fixed mounted operations as defined in 2 1091 and 1 1307 of the FCC rul...

Page 17: ...ications such as outdoor remote sensors There are other techniques to place the device into low power mode This example uses data terminal ready DTR and the AT command CFUN 5 For other techniques revi...

Page 18: ...current You can order the USB cable through MultiTech The part number is CA USB A MINI B 3 Powering Down Your Device CAUTION Failing to properly power down the device before removing power may corrup...

Page 19: ...HRA 10 ANPB2 50HRA 50 Antenna Requirements Specifications Frequency range 824 960 1710 2170MHz Impedance 50 ohm VSWR 2 5 1 Radiation Omni directional Polarization Linear horizontal Antenna System Cell...

Page 20: ...device has a unique phone number Your service provider supplies a phone number when you activate your account or if your device has a SIM card the phone number may be on it Wireless service provider...

Page 21: ...be something like dev ttyS0 for a serial build Save the file as etc ppp peers H5 peer Example peer file dev ttyACM0 connect usr sbin chat v f etc chatscripts H5 chat noipdefault usepeerdns defaultrou...

Page 22: ...EV3 peer This command line enables logging of debug information and tells pppd to use the peer file referenced by the call option After 20 30 seconds type ifconfig and check whether a ppp interface i...

Page 23: ...ABORT NO CARRIER ABORT BUSY at cgdcont 1 IP APN OK atd 99 1 CONNECT Step 3 Use the following command line to start pppd pppd debug call MAT1 peer This command line enables logging of debug informatio...

Page 24: ...from an FTP server In Linux PPPD is used to dial the modem and create the connection to the cellular TCP IP network This provides Internet access for sending and receiving email creating TCP UDP Sock...

Page 25: ...rength enter AT CSQ The command indicates signal quality in the form CSQ rssi ber Where rssi Received signal strength indication 0 113 dBm or less 1 111 dBm 2 30 109 dBm 53 dBm 2 dBm per step 31 51 dB...

Page 26: ...device is in a network searching state Sending and Receiving Data Connecting Device to TCP Server as TCP Client To send data through a connect socket 1 Define PDP Content APN for SIM Enter AT CGDCONT...

Page 27: ...rovider assigned to your SIM card 3 Verify device is registered on the cellular network Enter AT CREG Should return 4 Configure socket parameters Enter AT SCFG 1 1 300 240 600 50 5 Activate context on...

Page 28: ...ice To configure the device as a UDP client 1 Check signal strength Enter AT CSQ 2 If using a SIM card configure the APN Enter AT CGDCONT 1 IP XXX APN com where XXX APN com is the APN your cellular pr...

Page 29: ...using a SIM card configure the APN Enter AT CGDCONT 1 IP XXX APN com where XXX APN com is the APN your cellular provider assigned to your SIM card 3 Verify device is registered on the cellular network...

Page 30: ...0 The device responds with OK Transferring FTP File to FTP Server To connect to FTP server and upload files 1 Check signal strength Enter AT CSQ 2 If using a SIM card configure the APN Enter AT CGDCO...

Page 31: ...the file 1 Enter the escape sequence Enter The device responds with NO CARRIER 2 Close the FTP connection Enter AT FTPCLOSE 3 Close the PPP data connection Enter AT SGACT 1 0 The device responds with...

Page 32: ...der1 Enter AT FTPCWD folder1 9 Enter the file name Enter AT FTPGET filename txt where filename txt is the file you want to download The device responds with CONNECT The file is received through the de...

Page 33: ...ice responds OK 2 Enter the recipient s number and your message Enter AT CMGS Your message here where is the recipient s number 3 Send the message Enter CTRL Z The device responds CMGS OK where is the...

Page 34: ...Deletes all read and sent device originated messages Leaves unread messages and unsent device originated messages 3 Deletes all read messages and sent and unsent device orginated messages Leaves unrea...

Page 35: ...l Directive 1999 5 EC on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity Restriction of the Use of Hazardous Substances RoHS Multi Tech Systems...

Page 36: ...ch includes collection and validation of materials declarations and selective materials analysis where appropriate This data is controlled as part of a formal quality system and will be made available...

Page 37: ...REGULATORY INFORMATION MultiConnect Cell MTC G3 User Guide 37...

Page 38: ...Biphenyl PBB Polybrominat ed Diphenyl Ether PBDE Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O O O O O O...

Page 39: ...inese MII EIP 39 RoHS Multi Tech Systems Inc TS HS PB Hg CD CR6 PBB PBDE O O O O O O X O O O O O X O O O O O O O O O O O O O O O O O ICs O O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O...

Reviews: