SAFETY NOTICES
14
Conduit
®
IP67 Series 200 Base Station MTCDTIP2 Hardware Guide
Chapter 4 – Safety Notices
PoE Safety
Warnings and
Cautions
Warning and Caution symbols mean potential danger. You are in a situation that could cause bodily injury. Before
working on any equipment, be aware of hazards in the installation area and be knowledgeable about electrical
circuitry. Be familiar with standard practices for preventing accidents.
Warning:
Only trained and qualified personnel should install, replace, or service this equipment. Installation
must comply with local and national electrical codes.
Classification of use by: Skilled person.
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Externally ground this equipment using a customer-supplied ground wire before applying power.
Contact an electrician if you are uncertain that suitable grounding is available. Refer to
Installing
the Ground Wire
instructions in the
Installation Guide.
Disconnect PoE power (Ethernet PoE port) before servicing the device.
Do not work on the system or connect or disconnect cables during periods of lightning activity.
This device is not designed or approved to be used in any Hazardous Locations. Do not install or
operate device if area is known to be an explosive environment.
CAUTION:
Power over Ethernet (PoE) Certification does not apply or extend to voltages outside of standard PoE
range. PoE range for the MTCDTIP2 is 42.5-57 VDC.Any PoE voltages outside this range have not been
evaluated by UL or MULTITECH. The end user supplies the PoE cable. If the cable is to be used
outdoors, the cable must be certified for outdoor location.
Recommended PoE: 802.3at-compliant Type 2 Class 4 Power-over-Ethernet (PoE) Powered
Devices (PDs) and require PoE Power Supply Equipment (PSE) that is 802.3at-compliant with
minimum 25.5W output power capability.
This is an 802.3at Type 2 device. For more information, refer to the
Conduit PoE Application Note
(S000678).
Ethernet port is not designed to be connected to a public Telecommunication (PSTN) or any
other connection other than IEEE 802.3-2012 power over Ethernet devices.
Do not remove product labels.
Avertissement et mises en garde
Les symboles d'avertissement et de mise en garde indiquent un danger potentiel. Vous vous trouvez dans une
situation qui peut entraîner des blessures corporelles. Avant de travailler sur un équipement, vous devez être
conscient des dangers potentiels dans la zone d'installation et connaitre les circuits électriques. Familiarisez-vous
avec les pratiques normalisées de prévention des accidents.