background image

!

100  
250V AC
    

~

 

50/60 HZ
4VA

1

2

3

4

5

L

N

SSR

+

-

7

6

-

8

9

10

11

12

+  

-

T/C

NC

C

R1

NO

www.multispanindia.com

Page - 1

TC-49P

 2)

 

If Sensor is not Connected,  Display will show “



” message.

 3) To Show set point, press     Key.

Note:

 

 4) Auto out time is 15 sec without saving.
 5) Every time the instument is turn on,following pattern will be displayed.

Technical Specification

POWER ON

Display  for 3 sec 

display for 2 sec, according to the input
sensor programmed.

display for 2 sec, according to the control
action programmed.

Process Value

 







SET

SET

Connection Diagram  

3 Digit 7 seg 0.56”,red LED Display

       J type:  0 to 600°C 
       K type: 0 to 999°C 
       

PID/ ON-OFF (selectable)

Output 

 Power Supply

  Operating
Temperature

  Relative
 Humidity

100 to 250V AC,50/60 Hz, Approx 4VA

0°C To  55°C

Up to 95% RH Non Condensing

Model

Display

Size (mm)

Panel Cutout

Input

Temperature 
      Range

Control Action

48 (H) X 48 (W) X 70 (D) mm

44 X 44 mm

TC-49P

 J TYPE/ K TYPE

  1Relay, 1C/O Contact,5A, 230V AC
  S.S.R, 12V DC approx,10mA DC.

   Protection
      Level

   
      (As per request)

IP-65 (Front side) As per IS/IEC 60529 : 2001 



TC 49P

TUNE

°C

 1)

 

If Sensor Connection is reverse,  Display will show “



” message.

 

OPERATING MANUAL 

PID TEMPERATURE CONTROLLER                           

TC-49P

Reviews: