OPERATING MANUAL

SEQ. TIMER : 12 CHANNEL

Technical Specification

1) Model : SQT 1244
2) Display: 4 digit, Double Display
3) Input : NPN/PNP Proxy, Micro Switch.
4) Range :

1) 99.99 Sec.
2) 999.9 Sec.
3) 99.59 Min.
4) 99.59 Hrs.
5) 999.9 Hrs.

Mo

del : SQT 1044

Panel Cutout:

(96 X  96 mm)

(92 X  92 mm)

5) Relay Status : LED indicator

1) Relay status
2) Time unit

6) Timer Mode :

1) Delayed ON
2) Delayed OFF
3) Cycle Timer

7) Output : 12 Relay
8) Power Supply : 110 To 250V AC,

50/60 Hz SMPS

Note:

1) To make parameter setting easy, menu is devided in three groups.
2) Menu 1: is used to set the parameters which are needed to change

Frequently, like On time, OFF Time

3) Menu 2: is used to set the parameters like mode, range & No. Of cycles.
4) Menu 3: is used to set the parameters Which Needed to change in rare Case

like individual  & Common mode, Type of input & memory retention.

Working:

SET

SET

1) First enter in menu-3 (Short Terminal No.8 & 10 ) Then Power On.
2) Configure The instrument As per Your  Application
3) Press     +      Key & Follow Menu as per the Application.

4) Use     &     Key in Menu-1
5) At Any time press      key to save and exit.
6) To Change Any parameter     &     Key.
7) To go  to next parameter, Press      Key.
8)  If No. key is Pressed, Menu will Automatically exit after

15 SEC. without saving.