MULTISPAN PTC-4202A-M1 Manual Download Page 1

TECHNICAL SPECIFICATION

  3 P 3 w

TERMINAL CONNECTION

PTC-4202A-M1

MECHANICAL INSTALLATION

PROCESS TEMPERATURE CONTROLLER

PV

 = Process value

SV

 = Set Value

48

95

45

45

3

48

Outline Dimension (mm)

Panel Cutout 
Dimension (mm)

AO

O/P1

O/P2

TUNE

SET

ENT

RX
TX

AT

4485

PTC 4202A-M1

SV

PV

4500

Input Types

Resolution

Indication
Accuracy

Input  

Range

0 to 600°C, 

0 to 1200°C, 

-99 to 400°C, 

-99.9 to 400.0°C, 

-999 to 9999 

-999 to 9999 

-999 to 9999 

PT-100 

PT.1 

0-10V DC 

0-20mA DC 

4-20mA DC 

J,K,PT-100 = 1°C

±1% of FSD ± 1°C

PT.1 = 0.1°C

Display

Heating

Size 

Keys

Cooling

Panel Cutout

Upper: 4 digit, 7 segment, 0.39” White

1) PID control with Auto-Tuning

1) BL.TP (Blower Time Proportion)

Lower: 4 digit, 7 segment, 0.28” Green

2) ON-OFF control

2) ON-OFF control

48 (H) x 48 (W) x 95 (D) mm

SET, INC, DEC, ENT

45 (H) x 45 (W) mm

(FSD:- full scale deflection)

CONTROL METHOD:

INPUT SPECIFICATION:

DISPLAY AND KEYS:

DIMENSION:

CONTROL METHOD:

0-10V DC,0-20mA DC,4-20mA DC
= 0.1,0.01,0.001,0001

OUTPUT SPECIFICATION

AUXILIARY SUPPLY

Relay

Supply voltage

Relay Type

Power consumption
(VA RATING)

Rating

2 nos.

(NO-C)

Approx 7 VA @ 230V AC MAX

5A, 230V AC/30 V DC

ENVIRONMENT CONDITION

Relative Humidity

Protection 
Level

 Operating Temp.

0°C to 55°C

UP to 95% RH 
(non-condensing)

IP-65 (Front side) As per IS/IEC
60529 : 2001

100 to 250V AC, 50-60Hz

Relay Output

Analog Output

Controlling Output

4 to 20mA DC

R1

C

NO

1

2

3

4

5

L

N

100  
250V AC
    

~

 

50/60 Hz
7VA

www.multispanindia.com

Made in India

PTC 4202A-M1-WG

  +

  -

O/P

4-20mA 

DC

    

     
RS

    485

MODBUS

   D +

   D -

T/C

+

+

0/4-20

mA DC

0-10V DC

6

7

8

9

10

-

RTD

C

NO

R2

!

Summary of Contents for PTC-4202A-M1

Page 1: ...Lower 4 digit 7 segment 0 28 Green 2 ON OFF control 2 ON OFF control 48 H x 48 W x 95 D mm SET INC DEC ENT 45 H x 45 W mm FSD full scale deflection CONTROL METHOD INPUT SPECIFICATION DISPLAY AND KEYS...

Page 2: ...cilitate power ON or OFF function However this mains switch or circuit breaker must be installed at convenient place normally accessible to the operator 4 Use and store the instrument within the speci...

Page 3: ...T R C PB C ON C OF HYS1 M Hysterisis 2 HYS2 S T SOA OUT1 S UT OutPut 1 Mode Soak Time Select Soak Mode Soak Unit Soak Time Value h h h E O Soak Time Memory Alarm 2 Set 2 Mode Relay 1 Delay Time Relay...

Page 4: ...9 0 C 20 0 to 20 0 C Range for Analog Input 0 0 to 999 9 0 to 9999 0 to 9999 4 to 99 sec 0 001 to 0 999 1 to 20 sec 2 0 to 25 0 5 to 200 sec 0 0 to 99 59 mm ss 0 0 to 99 59 mm ss 0 to 99 sec 0 009 to...

Page 5: ...ntrolling Analog O P Controlling Press key SET Press key SET Press key SET Press key SET Press key SET ALM2 IN B AB O ALM1 IN B AB O ALM1 IN B AB O S1MD INDI S2MD INDI Press key SET Return to Paramete...

Page 6: ...se 4 Heat Alarm Case 11 Heat Alarm Case 5 cool cool Case 12 cool cool Case 6 cool alarm Case 13 cool alarm Case 7 alarm alarm Case 14 alarm alarm Input J K PT PT 1 Input 0 10V DC 0 20mA DC 4 20mA DC A...

Page 7: ...If ON OFF Selected Heat Soak Alarm Case 1 Heat Heat Case 2 If PID Selected If ON OFF Selected If PID Selected If ON OFF Selected Heat Cool Case 3 Heat Alarm Case 4 Cool Cool Case 5 Cool Alarm Case 6...

Page 8: ...Alarm Case 7 14 SOAK ALRM ALRM Case 8 Heat Heat Case 9 IF HIGH AB L IF IN B AB 0 IF Individual IF Relative IF HIGH AB L IF IN B AB 0 Heat Cool Case 10 Heat Alarm Case 11 Cool Alarm Case 13 Cool Cool...

Page 9: ...Lower then SLL Heat Cool Alarm Off Mode Value 0 1 2 3 Selection 0 40mA DC On Off Value 1 0 Selection Note When Parameter 32100 no available When Process Value 32101 Initialization Value R W R W R W R...

Page 10: ...at Cool Alarm Off Mode Value 0 1 2 3 Selection Pid On Off Blower TP Value 0 1 2 Selection Pid On Off Blower TP End Alarm Abs Low High Alarm In Band Abs Out Band Value 0 1 2 3 4 Selection R W R W N A R...

Page 11: ...0mA DC Actual Value Value 1 Value 1 Value 10 Value 10 Value 100 Fix Fix Value 10 Value 100 Value 1000 Where Parameter is 1 6 14 19 25 32 44 46 48 49 57 69 70 Where Parameter is 5 20 26 33 Where Parame...

Reviews: