MULTISPAN MMC-1046T Operating Manual Download Page 1

www.multispanindia.com

Page - 4

MMC-1046T

Product improvement and upgrade is a constant procedure. So for more updated operating information and support, 
Please contact our helpline : +91-9978991474/76/82 or Email at [email protected]                   Ver: 1901

Note:

UPPER:- 6 Digit 7 seg 0.56”,red LED Display

LOWER:- 4 Digit 7 seg 0.4”,green LED Display

        NPN Proxy, NPN Color mark sensor (CMS),
                                  Micro switch

        0 To 99.99 Second

Output 

 Power Supply

  Operating
Temperature

  Relative
 Humidity

100 to 270V AC,50/60 Hz, Approx 4VA

0°C To  55°C

Up to 95% RH Non Condition

Model

Display

Size (mm)

Panel Cutout

Range

      Input

96 (H) X 96 (W) X 50 (D) mm

92 X 92 mm

MMC-1046T

  1Relay, 1C/O 230V AC
     

IP-65 (Front side) As per IS/IEC 60529 : 2001 

   Protection
      Level

www.multispanindia.com

Page - 1

MMC-1046T

OPERATING MANUAL 
PROGRAMABLE COUNTER  

MMC-1046T

Technical Specification

Working

RESET

1. Make all connection properly according to the “Connection Diagram”. Then ON the 
    instrument, set the “Set Time” according to your requirement press      key 
    to store new value in memory.

2. When a pulse Input is given to NPN Proximity sensor, than Upper Display will increase 
    Counts & Timing will start in Lower Display. Between running time if Pulse of CMS is 
    given than timing will stop. At the end of Timing Relay will turn Off.
  
3. If you don’t press any key for 5 seconds, the previous value of set point is retained and
    the instrument goes in to run mode.

4. Press       to store set value in memory, simultaneously instrument goes in run mode. 
    only after Press      key the new value is stored.

5. If you want to reset your instrument Press      key.        
     