DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07) — PAGE 55
1
1. Perform steps 1 through 6 in the
Before Starting
section
as outlined in the
Manual Starting
Procedure
.
2. Place the
engine speed switch
(Figure 54) in the
HIGH
position
4. Continue operating the generator as s outlined in the
Manual Start-up
procedure (start at step 5).
Figure 55. MPEC Control Switch (AUTO)
When running the generator in the
AUTO
mode, remember
the generator can start up at any time without warning.
NEVER
attempt to perform any maintenance when the
generator is in the auto mode.
WARNING - AUTO MODE MAINTENANCE
DCA-150SSJU3 — GENERATOR START-UP PROCEDURE (AUTO MODE)
When the
MPEC
Control Switch
is placed in the
AUTO
position,
the engine glow plugs will be
warmed and the engine will start
automatically.
NOTE
When starting generator in
AUTO
mode use the "
Manual
Start-up
" procedure except where noted (see below).
CAUTION - ENGINE SPEED SWITCH
The
Engine Speed Switch
must
be set to the “
High
”
position when running in the
Auto-Start
mode. Failing to
set the switch in the proper position can result in damage
to your generator when it turns on.
3. Place the
MPEC Control Switch
(Figure 55) in the
AUTO
position