PAGE 34 — GAW180HE/HEA WELDER-GENSET • OPERATION AND PARTS MANUAL — REV. #1 (10/01/19)
BATTERY
This unit is of negative ground.
DO NOT
connect in reverse.
Always maintain battery fluid level between the specified
marks. Battery life will be shortened, if the fluid levels are
not properly maintained. Add only distilled water when
replenishment is necessary.
Check to see whether the battery cables are loose. Poor
contact may result in poor starting or malfunctions. Always
keep the terminals firmly tightened. Coating the terminals
with an approved battery terminal treatment compound
will help prevent corrosion. Replace battery with only
recommended type battery.
The battery is sufficiently charged if the specific gravity
of the battery fluid is 1.28 (at 68° F). If the specific gravity
should fall to 1.245 or lower, it indicates that the battery is
dead and needs to be recharged or replaced.
Before charging the battery with an external electric source,
be sure to disconnect the battery cables.
BATTERY CABLE INSTALLATION
ALWAYS
be sure the battery cables are properly connected
to the battery terminals (Figure 36). The
red
cable is
connected to the positive terminal of the battery, and the
black
cable is connected to the negative terminal of the
battery.
Figure 36. Battery Connections
NOTICE
Inadequate battery cable connections may cause poor
starting of the generator, and create other malfunctions.
POSITIVE
NEGATIVE
MAINTENANCE
When connecting battery do the following:
1.
NEVER
use worn or damaged battery cables. Replace
defective battery cables immediately.
2. Place a small amount of battery terminal treatment
compound around both battery terminals. This will
ensure a good connection and will help prevent
corrosion around the battery terminals.
POLARITY
The polarity of the battery is extremely important. When an
inverted circuit connection takes place, the circuit will be in
short circuit instantaneously resulting in possible damage
to the control box electronics and starter.
When connecting the battery cables to the battery terminals
be sure to check the polarity.
NOTICE
ALWAYS
disconnect the negative terminal first and
reconnect negative terminal last.
NOTICE
If the battery cables are connected incorrectly, electrical
damage to the generator will occur. Pay close attention
to the polarity markings on the battery when connecting
the battery cables.
Summary of Contents for GAW180 Series
Page 5: ...GAW180HE HEA WELDER GENSET OPERATION AND PARTS MANUAL REV 1 10 01 19 PAGE 5 NOTES...
Page 39: ...GAW180HE HEA WELDER GENSET OPERATION AND PARTS MANUAL REV 1 10 01 19 PAGE 39 NOTES...
Page 46: ...PAGE 46 GAW180HE HEA WELDER GENSET OPERATION AND PARTS MANUAL REV 1 10 01 19 GENERATOR ASSY...
Page 48: ...PAGE 48 GAW180HE HEA WELDER GENSET OPERATION AND PARTS MANUAL REV 1 10 01 19 CONTROL BOX ASSY...
Page 50: ...PAGE 50 GAW180HE HEA WELDER GENSET OPERATION AND PARTS MANUAL REV 1 10 01 19 CONTROL BOX ASSY...
Page 52: ...PAGE 52 GAW180HE HEA WELDER GENSET OPERATION AND PARTS MANUAL REV 1 10 01 19 PIPE FRAME ASSY...
Page 54: ...PAGE 54 GAW180HE HEA WELDER GENSET OPERATION AND PARTS MANUAL REV 1 10 01 19 PIPE FRAME ASSY...
Page 56: ...PAGE 56 GAW180HE HEA WELDER GENSET OPERATION AND PARTS MANUAL REV 1 10 01 19 BATTERY ASSY...
Page 58: ...PAGE 58 GAW180HE HEA WELDER GENSET OPERATION AND PARTS MANUAL REV 1 10 01 19 MUFFLER ASSY...