COMpOnents (generatOr)
Figure 3. Generator Components
1.
gFCi Breakers (2) –
These single pole circuit breakers
(120V, 15 amps) protect the GFCI receptacles. When
starting the generator always have these circuit
breakers placed in the "
OFF
" position.
2.
30 amp Breaker –
Single pole 30 amp circuit breaker
protects the 120V twist-lock receptacle. When starting
the generator always have this circuit breaker placed
in the "
OFF
" position.
3.
20 amp Breaker –
2-pole 20 amp circuit breaker
protects the 240V twist-lock receptacle. When starting
the generator always have this circuit breaker placed
in the "
OFF
" position.
4.
30 amp Breaker –
2-pole 30 amp circuit breaker
protects the 120/240V twist-lock receptacle. When
starting the generator always have this circuit breaker
placed in the "
OFF
" position.
5.
aC-voltmeter –
This voltmeter indicates (with a
mark) the rated 60 Hz (single-phase) output voltage.
In addition the voltmeter can also be used as a
diagnostic tool. If the voltmeter indicator (needle) is
below the rated voltage, engine problems may exist
(low/high RPM's). To prevent damage to the generator
or power tools turn the generator
OFF
and consult your
authorized Multiquip service dealer.
6.
idle Control switch –
The generator is provided with
an automatic idle control device for noise suppression
and reduced fuel consumption.
The automatic idle control automatically engages under
a no-load condition. With the automatic idle control
switched “
ON
”, the engine revolutions will automatically
drop to about 2600 rpm (low-speed operation) within
3 seconds after the load stops. When the operation is
resumed, the engine speed is automatically increased
to about 3600 rpm (high-speed operation) as soon as
the load is connected.
7.
Operation switch –
Place switch in the "
ON
" position
(up) for normal operation. To turn-off the generator,
place the operation switch in the "
OFF
" position (down).
8.
start Button –
Press this pushbutton switch to start
the generator.
9.
main Breaker –
2-pole 35 amp circuit breaker protects
the generator from short circuiting or overloading.
When starting the generator always have this circuit
breaker placed in the "
OFF
" position.
10.
120/240v Output Receptacle –
NEMA L14-30R twist-
lock receptacle will provide 120/240V, 30 amps, 60 Hz.
11.
240v Output Receptacle –
NEMA L6-20R twist-lock
receptacle will provide 240V, 20 amps, 60 Hz.
12.
120v Output Receptacle –
NEMA L5-30R twist-lock
receptacle will provide 120V, 30 amps, 60 Hz.
13.
gFCi duplex Receptacle –
NEMA 5-15R, GFCI
receptacle will provide 120V, 15 amps.
14.
ground lug –
This ground connection point should be
connect to a good earth ground (ground rod).
Summary of Contents for GAC-9.7HZ
Page 9: ...GAC9 7HZ 60 hz GENERATOR operation and parts manual rev 2 03 31 10 page 9 NOTES...
Page 13: ...GAC9 7HZ 60 hz GENERATOR operation and parts manual rev 2 03 31 10 page 13 note...
Page 33: ...GAC9 7HZ 60 hz GENERATOR operation and parts manual rev 2 03 31 10 page 33 notes...
Page 87: ...GAC9 7HZ 60 hz GENERATOR operation and parts manual rev 2 03 31 10 page 87 notes...