GA-3.6H SERIES A.C. GENERATORS — OPERATION & PARTS MANUAL — REV. #0 (11/01/05) — PAGE 17
This
HONDA
engine is equipped
with a low oil shutdown capability. A
built in sensor will automatically turn
off the engine should the oil level fall
below a safe operating condition.
Make sure the generators is placed
on level ground. Placing the generators on level ground will
ensure that the low oil sensor will function properly.
NOTE
GA-3.6H Series— CONTROLS AND INDICATORS
14
. Fuel Cock Lever –
Turn this lever
downward
to
start
(down)the flow of fuel into the carburetor. Turn
upward
to
stop (
up
)
the flow of fuel.
15
. Spark Plug –
Provides spark to the ignition system. Set
spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch) Clean
spark plug once a week.
16
. Muffler/Heat Shield –
Used to reduce noise and emissions.
NEVER
touch this
heat shield
when the generator/welder
is in use. Always allow time for the generators to cool down
before performing maintenance.
17
. Choke Lever –
Used for starting the engine.
Close
the
choke lever when starting a cold engine or in cold weather
conditions. The choke enriches the fuel mixture.
Open
the
choke lever if starting a warm engine or in warm weather
conditions.
18
. Recoil Starter (pull rope) –
Manual-starting method. Pull
the starter grip until resistance is felt, then pull briskly and
smoothly.
19.
Engine Oil Filler Cap –
Remove this cap/dipstick when
the adding of engine oil is required. See Table 4 for
recommended type engine oil.
Figure 2E. Generators Components
20.
Engine Oil Drain Plug –
Remove this drain plug when
draining of the oil from the engine crankcase is required.
Fill with recommeded type oil as listed in Table 4.
21
. Air Cleaner –
Prevents dirt and other debris from entering
the fuel system. Remove wing-nut on top of air filter
cannister to gain access to filter element.
NEVER
run the
engine without an air cleaner.
22
. Fuel Tank Cap –
Remove this cap to add unleaded
gasoline to the fuel tank.
Replenish
with
clean unleaded
gasoline. Make sure cap is tightened securely.
DO NOT
over fill.
23
. Fuel Gauge –
This gauge is located on top of the fuel tank.
Read this gauge to determine when fuel is
low
.
24
. Fuel Tank –
Fuel tank capacity is 5 gallons (19 liters).
Models GA3.6H and GA3.6HA shown.
Componet location for GA3.6HZ is
similar.
NOTE
Summary of Contents for GA-3.6HZ
Page 2: ...PAGE 2 GA 3 6H SERIES A C GENERATORS OPERATION PARTS MANUAL REV 0 11 01 05...
Page 3: ...GA 3 6H SERIES A C GENERATORS OPERATION PARTS MANUAL REV 0 11 01 05 PAGE 3 NOTE PAGE...
Page 35: ...GA 3 6H SERIES A C GENERATORS OPERATION PARTS MANUAL REV 0 11 01 05 PAGE 35 NOTE PAGE...
Page 85: ...GA 3 6H SERIES A C GENERATORS OPERATION PARTS MANUAL REV 0 11 01 05 PAGE 85 NOTE PAGE...