12
Part Number: 9290312 October/22/2018
REMOTE TOWER INSTALLATION
These instructions are only for units that require remote
placement of the dispensing tower. If this is a self contained
unit with out remote setup continue to “Nitrogen Regulator
& Tank Assembly” on page 13.
Checklist
Tower location should be no more than 20.70"
(53 cm) from edge of the counter.
Mount tower within 6 linear ft (1.83 m) from side of
base cabinet.
Make sure location has space for the drip tray
shipped with the unit.
NOTE: Drip trays equipped with a drain are also available
but are not standard equipment.
Location
1. Identify the counter top location for the tower making
sure there is room for the drip tray, conduit routing
under the counter, and is away from any heat source.
IIportant
If the drip tray is equipped with a drain make sure install
location is near a floor drain.
2. Using the provided counter top template mark where
the 2" (5 cm) conduit and tower mount screw holes will
be drilled.
3. Cut and drill holes in the counter using the markings.
NOTE: Drip trays equipped with a drain will need a 7/8"
(2.22 cm) hole drilled into the counter using the provided
template for routing to a floor drain.
Mounting & Routing
IIportant
Make sure the rubber counter top gasket is in place on
the tower before routing conduit and mounting tower.
To Cabinet
TAP #1
Plain
TAP #2
Nitro/Gas
4. Route conduit from the tower down through the 2in
(5 cm) hole and mount the tower to the counter top
with the provided plate and screws.
NOTE: Make sure the rubber gasket is properly seated on
the tower and seals to the counter top.
5. Run the conduit from the tower to the N
2
Fusion™ cabinet.
6. Remove the two (2) screws from the solenoid cover
mounted to the inside top of the cabinet to gain access
to solenoids 1 and 2.
7. Route tubing through the top of the cabinet and attach
to the corresponding solenoids.
NOTE: Tubing already routed to the solenoids in the cabinet
should be marked with yellow 1 & 2 stickers.
n
Warning
Do not add line to the conduit this can cause poor drink
quality and the unit may not perform properly.