![Multiplex MB-8-1 Technician'S Handbook Download Page 148](http://html1.mh-extra.com/html/multiplex/mb-8-1/mb-8-1_technicians-handbook_1854679148.webp)
148
HIGH PRESSURE CUTOUT (HPCO) CONTROL
FUNCTION
Stops the ice machine if subjected to excessive high-
side pressure. The HPCO control is normally closed,
and opens on a rise in discharge pressure.
SPECIFICATIONS.
Specifications
Cut-Out
Cut-In
2930 kPa ±29.30 bar ±.69
425 psig ±10
Automatic Reset
Must be below 1978 kPa 19.78 bar (287 psig) to reset.
Summary of Contents for MB-8-1
Page 22: ...22 Part Number STH034 3 12 This Page Intentionally Left Blank...
Page 24: ...24 Part Number STH034 3 12 Dimensions A 26 00 66 cm B 32 82 83 cm A B Elevation View...
Page 26: ...26 Part Number STH034 3 12 G 32 82 83 cm J 39 09 99 cm I 36 15 92 cm G I J Side View...
Page 96: ...96 Part Number STH034 3 12 This Page Intentionally Left Blank...
Page 158: ...158 Part Number STH034 3 12 This Page Intentionally Left Blank...
Page 164: ...164 Part Number STH034 3 12 This Page Intentionally Left Blank...
Page 169: ...Part Number STH034 3 12 169 VERSION 1 ICE MACHINE R404A REFRIGERANT ICE MACHINE WIRING DIAGRAM...
Page 170: ...170 Part Number STH034 3 12 VERSION 1 ICE MACHINE R404A REFRIGERANT ICE MACHINE LOGIC DIAGRAM...
Page 175: ...Part Number STH034 3 12 175 VERSION 2 ICE MACHINE R290 REFRIGERANT ICE MAKER WIRING DIAGRAM...
Page 177: ......