background image

You have just purchased a 

DMM111 digital multimeter 

and we thank you for your confidence.

For best results from your instrument:

 

„

read these operating instructions carefully,

 

„

comply with the precautions for use.

PRECAUTIONS FOR USE

This instrument and accessories are compliant with 
safety standards IEC 61010-1, IEC 61010-031 and 
IEC 61010-2-033 for voltages up to 600V in category III.
Failure to observe the precautions for use and safety 
instructions may cause an electric shock, fire, explosion, 
or destruction of the instrument and of the installations.

 

„

The operator and/or the responsible authority must 
carefully read and clearly understand the various 
precautions to be taken in use. 

 

„

If you use this instrument other than as specified, the 
protection it provides may be compromised, thereby 
endangering you.

 

„

Do not use the instrument on networks of which the 
voltage or category exceeds those mentioned.

 

„

Observe the environmental conditions of use.

 

„

Do not exceed the rated maximum voltages and 
currents between terminals or with respect to earth.

 

„

Do not use the instrument if it seems to be damaged, 
incomplete, or poorly closed.

 

„

Before each use, check the condition of the insulation 
on the leads, housing, and accessories. Any item of 
which the insulation is deteriorated (even partially) must 
be set aside for repair or scrapping.

 

„

Use only the leads and accessories supplied. Using 
leads (or accessories) of a lower voltage or category 
reduces the voltage or category of the combined 
inst leads (or accessories) to that of the leads 
(or accessories).

 

„

Use personal protective equipment when conditions 
require.

 

„

When handling the leads, test probes, and crocodile 
clips, keep your fingers behind the physical guard.

 

„

Keep your hands away from the terminals of the 
instrument.

 

„

Replace the battery as soon as the  

 symbol appears 

on the display unit. Disconnect all leads before opening 
the battery compartment cover.

PRESENTATION

The DMM111 is a device for measuring electrical 
quantities:

 

„

AC or DC voltage measurement;

 

„

DC and AC current measurement;

 

„

Resistance measurement, continuity measurement 
with buzzer or diode test.

SWITCHING OFF THE MULTIMETER
Manual switching off  
Set the switch to 

OFF.

Automatic power down

CHANGING RANGES 

>2s

The automatic power down function of the device is 
reactivated when the device is switched back on.

CHANGING MODES 
Several modes may be available for a given function 
(existence of additional modes indicated by a yellow 
symbol). Press the SELECT key to change which mode 
is active.

SELECT

USE

INSERTING THE BATTERIES 
See § Maintenance.

TEST OF OPERATION

RANGE

MAX

SELECT

HOLD

MULTIMETER

10A

OFF

OFF

DMM 111 

 

LCD display 
unit

Keys

Switch

Impact-resistant 
jacket

Input 
terminals

Battery 
compartment 
cover

Prop

OFF

OFF

RANGE

MAX

SELECT

HOLD

OFF

OFF

DMM 111 

RANGE

MAX

SELECT

HOLD

OFF

OFF

DMM 111 

15 min

OFF

OFF

+

RANGE

MAX

SELECT

HOLD

OFF

OFF

HOLD OF THE DISPLAY

OFF

OFF

RANGE

MAX

SELECT

HOLD

RANGE

MAX

SELECT

HOLD

OFF

OFF

MEASUREMENTS

 The input voltage must not exceed 600V.

AC voltage measurement

OFF

OFF

RANGE

MAX

SELECT

HOLD

Definition of measurement categories

 

„

Measurement category IV corresponds to 
measurements taken at the source of low-voltage 
installations.

 

„

Measurement category III corresponds to 
measurements on building installations.

 

„

Measurement category II corresponds to 
measurements taken on circuits directly connected 
to low-voltage installations.

+

HOLD

Resistance measurement  

Diode test 

OFF

OFF

OFF

OFF

Continuity test 

DC current measurement

MAX FUNCTION

Battery 
compartment 
cover screws

DMM111

Multimeter

R < 90 

Ω = 

 

OFF

OFF

De-activating the automatic power down

 

m

DC voltage measurement

OFF

OFF

RANGE

MAX

SELECT

HOLD

Resistance and capacitance measurements 
and diode and continuity tests must be 
performed on voltage-free circuits.

AUTO RANGE

AUTO RANGE

AC current measurement

SELECT

RANGE

MAX

HOLD

RANGE

MAX

SELECT

HOLD

MULTIMETER

10A

OFF

OFF

DMM 111 

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

SELECT

+

SELECT

+

SELECT

+

RANGE

MAX

SELECT

HOLD

µA

mA

A

µA

mA

A

SELECT

 

 

+

SELECT

GB

WARNING, risk of DANGER! The operator 
must refer to this user’s manual whenever this 
danger symbol appears.
 
Equipment protected by double insulation.

Earth. 

Instruction that must be read and understood.

AC - Alternating current.

DC - Direct current.

Battery.

The CE marking indicates conformity with 
European directives.

The rubbish bin with a line through it means 
that in the European Union, the product 
must undergo selective disposal for the 
recycling of electric and electronic material, 
in compliance with Directive WEEE 2002/96/
EC. This equipment must not be treated as 
household waste.

RANGE

RANGE

RANGE

MAX

HOLD

RANGE

MAX

SELECT

HOLD

Reviews: