![multicomp pro MP720021 Manual Download Page 100](http://html1.mh-extra.com/html/multicomp-pro/mp720021/mp720021_manual_1854297100.webp)
User Manual
95
4.
At the mode of Autoscale, DSO is always set as DC coupling with AUTO
triggering, the holdoff is set to 100ns.
5.
At the mode of Autoscale, if adjust the vertical position, voltage division, trigger
level or time scale, the oscilloscope will pause the Autoscale function. To resume
Autoscale, push the
Autoset
front panel button.
6.
When video triggering, the horizontal time scale is 50us.
7.
While the Autoscale is working, the settings below will be made forcibly:
The DSO will switch from the wave zoom mode to the normal mode.
In the decoding, pass/fail or XY mode, when entering into Autoscale, these modes
will be turned off.
In the STOP status, when entering into Autoscale, the status will be set to RUN.
How to Use Built-in Help
1.
Push
Help
button, the catalog will display in the screen.
2.
In the bottom menu, press
Prev Page
or
Next Page
to choose help topic, or just
turn the
M
rotary control to choose.
3.
Press
OK
to view the details about the topic, or just push the M rotary control.
4.
Press
Quit
to exit the help, or just do other operations.
How to Use Executive Buttons
Executive Buttons include
Autoset, Run/Stop, Single, Copy
.
Autoset
It's a very useful and quick way to apply a set of pre-set functions to the incoming
signal, and display the best possible viewing waveform of the signal.
The details of functions applied to the signal when using
Autoset
are shown as
the following table:
Function Items
Setting
Channel Coupling
DC
Vertical Scale
Adjust to the proper division.
Vertical Position
Adjust to the proper position.
Bandwidth
Full
Horizontal Level
Middle
Horizontal Sale
Adjust to the proper division
Trigger Type
Slope or Video
Trigger Source
The previous source before autoseting.
When the previous source has no input signal, the source
will be set to the minimum channel which has input
signal.
When all the channels have no input signal, the source
will be set to CH1.
Trigger Coupling
DC
Trigger Slope
Rising edge
Summary of Contents for MP720021
Page 1: ...i Digital Storage Oscilloscope 100MHz Model MP720025...
Page 5: ...v Appendix B General Care and Cleaning 147 Appendix C Battery Using Guide 148...
Page 27: ...User Manual 22 Control the vertical cursor line Switch to select the lines...
Page 36: ...User Manual 31 Figure 4 1 Hamming window Figure 4 2 Rectangle window...
Page 37: ...User Manual 32 Figure 4 3 Blackman window Figure 4 4 Hanning window...
Page 38: ...User Manual 33 Figure 4 5 Kaiser window Figure 4 6 Bartlett window...