FS
4
Innovation. Quality. Performance. Best in Industry. Worldwide.
Fast Start Oxyacetylene Torch
1.
Turn on Power
Locate the Power switch, the round knob located on the control enclosure.
Rotate to the ON position.
2.
Turn on Air Pressure
Verify the pressure per Manufacturer’s recommendations.
3.
Open Gas Bottles
Verify pressure per Manufacturer’s recommendations.
4.
Find Machine Hard Home
Press
Shift
and
Go Home
to find the Hard Home 0,0 or the Machine Home by indexing the gantry,
carriage, and Z assembly off of the proximity limit switches.
5.
Set System to Oxyfuel
Turn the Torch Selector switch from Plasma to Oxyfuel.
6.
Set Home
Press
Jog Speed
to set the speed of the movement to slow, medium, or fast.
Press
Jog Arrows
to place the
center of the torch
over the front right corner of the
material.
Press
Set Home
to set the home location for the oxyacetylene torch. The system will prompt the
operator as to whether the selected position should be set as Home, and the display will read “Press Down
to set Rotation Point.” See Rotate File for a description of this function.
Press
Enter
to confirm the position.
7.
Select Material To Be Cut
Press
Material Library
.
Press
Jog Arrows
to select the correct material.
Press
Enter
to access the parameters for that material.
Select the current amperage and material thickness from the material library.
Routers * Lasers * Plasma * Water Jets * Knife Cutters
www.MultiCam.com v. 03 13