The RouteFinder

 Model MTASR1-100 is a 1-Port 10BaseT/10Base2 Router for the Global market.  The

following is a procedure for testing an MTASR1-100 router and the composite link cable in synchronous
mode. Multi-Tech routers will connect to themselves and proceed to send packets into a modem in
synchronous loopback mode and receive the same packets back.

Synchronous Mode Test Procedure

Router Configuration

1.

Start the RouteFinder configuration software, and access the MTASR1-100.  The following are the
special settings needed for this test.

2.

Click the “IP” button, and then access the “Ethernet” tab.  Verify that a valid IP address is assigned to
the Ethernet port of the MTASR1-100 router, and that Authentication is set to “No Authentication.”

3.

Click the WAN tab.  Check “IP Port Enable” and “Unnumbered Link.”

4.

Click the Advanced tab.  Check “Routing”, and uncheck “RIP.”  Click “OK” to return to the main
configuration screen.

5.

Click the “PPP/SLIP” button, and then access the “WAN” tab.  At the bottom of the window, check
“Client or LAN” for Remote Port Setup.  Click “OK” to return to the main configuration screen.

6.

Click the “WAN” button, and then access the “WAN” tab.  Check “Port Enable.”  Under “Mode”,
check “synchronous”, “external clock”, “Send Idle Flags.”  Under “Connection Method”, check
“Direct Connect/Lease Line.”  Click “OK” to return to the main configuration screen.

7.

Click the “Frame Relay” button, and uncheck the “Enable” box.  Click “OK” button to return to the
main configuration screen.

8.

Click “Download Setup” to load the new settings into the MTASR1-100 router.  Switch the MTASR1-
100 router off.

Modem Configuration and Setup

9.

Disconnect the MT2834BLI modem attached to the MTASR1-100 modem from the lease line.

10. Set the MT2834BLI modem to the following DIP switch settings:  SW1 and 11 down; SW2-10,

SW12-16 up.

11. Turn the MT2834BLI modem off.
12. Hold the Ans/Org (Voice/Data) switch on the modem in the down position.  While continuously

holding the Ans/Org switch in the down position, switch the MT2834BLI modem back on.

13. Continue to hold Ans/Org switch in the down position until five seconds after the modem lights have

ceased to cycle.

14. The CD and TR lights, plus a speed light (probably a 33 light, flashing) on the modem will light.  The

MT2834BLI modem is now in loopback mode, using synchronous data protocol.  Data sent to the
modem will be sent directly back to device attached to the modem.