9
"Tank Control II" menu - Filling and operation
Controlling external devices
50
V2.20161017
30252060-02-EN
You can set the start or stop time of the two devices relative to one another. The options are shown in
the two tables below:
Set the start time
Start time icon
Meaning
The ball valve opens when the filling pump starts.
The ball valve opens before the filling pump starts, in this case: 5
seconds earlier.
The ball valve opens after the filling pump has reached the set
speed, in this case: 5 seconds later.
Set the stop time
Stop time icon
Meaning
The ball valve shuts when the filling pump stops.
The ball valve shuts before the filling pump stops, in this case: 5
seconds earlier.
The ball valve shuts after the filling pump has switched off, in this
case: 5 seconds later.
Using an agitator
There are two types of agitator:
▪ Agitator with on/off valve
▪ Agitator with rotary speed control
The settings that you can enter differ according to the type of agitator. The following settings are
available:
Function icon or
key
Meaning
Change mode
Change status
Increase speed