Configuring the job computer
Calibrating the flow meter
7
30303187-02-EN
V1.20180921
63
⇨
The following screen appears:
⇨
The current flow appears on the “Measured flow” line.
4.
- Start application
5.
Go to one of the nozzles and carefully collect the water sprayed for 60 seconds by using the
prepared measuring cup.
6.
Write down the applied water volume.
7.
Repeat the last two steps on several nozzles.
8.
Calculate and write down an average of several measurements.
9.
- Stop application.
⇨
The application will be stopped.
10.
- Stop calibration.
⇨
On the „3. Enter real volume per nozzle ” line, an input box appears.
11.
Enter the average applied volume in litres in this box.
12.
- Exit the screen.
⇨
The value of the “Impulses main flow” parameter will be updated.
⇨
You have calibrated the flow meter with the nozzle method.
Manually entering the number of impulses per liter for the flow meter
If you know the precise number of impulses per liter for the flow meter, you can enter this value
manually.
1.
Switch to the “FLOW METER” screen:
>
>
2.
Enter number of impulses per litre on the “Impulses main flow” line.
Combining the flow meter with the pressure sensor
If a pressure sensor is installed on the sprayer, you can combine the regulation via the flow meter
and the pressure sensor. This enables more stable regulation even at low flow rates.
7.3.3
Procedure
7.3.4