4
Mounting and installation
Installing the job computer
20
V1.20180921
30303187-02-EN
Mounting and installation
Installing the job computer
Instructions for safe installation
To prevent damage to the system components, consider the following during installation:
▪ Install the job computer where it is protected from dirt. You therefore avoid unintentional cleaning
of the job computer by the implement operator using a high-pressure cleaner.
▪ In the installed position, the connectors and the pressure compensation membrane must be
facing to the side.
▪ Fasten the job computer with four fixing bolts and a flat washer (lock washers can cause cracks
in the plastic on the long term) on a conducting spot on the implement chassis. In case of
improper installation, the ESD discharges can cause malfunctions.
▪ All of the sockets and connectors that are not used must be protected from dust and water using
suitable dummy connectors.
▪ All of the connectors must be tightly sealed. This makes them waterproof.
▪ Do not use the system if some of its parts are damaged. Damaged parts can cause malfunctions
and lead to injuries. Replace damaged components or repair them if possible.
▪ Use only original components manufactured by Müller-Elektronik.
Connecting the AMP connectors
This is how to connect two AMP connectors:
1.
Pull out the red locking device of the AMP socket all the way to the end.
⇨
You will hear a loud clicking sound.
⇨
The openings for inserting the locking pins of the connector are visible.
2.
Insert the connector into the socket. It should be possible to easily insert the locking pins in the
openings.
⇨
The connector is loosely inserted in the socket.
3.
Press in the red locking device.
⇨
You will hear a loud clicking sound.
⇨
A part of the locking device comes through to the other side of the socket.
4
4.1
4.1.1
4.1.2
Procedure