Configuring TRAIL-Control
Configuring the speed sensor
6
30322332-02-EN
V2.20160912
29
⇨
The following screen appears:
2.
Set up the implement on flat ground in a line behind the tractor. Drive straight for a few meter
until the tracks of the field sprayer run precisely into the tracks of the tractor.
or
– set the middle position with the function keys.
3.
Stop the tractor as soon as the field sprayer is exactly in line behind the tractor.
4.
Drive straight ahead very slowly. While driving, the friction of the wheel corresponds to the real
working conditions and the system can work more precisely later. However, you can also
perform this calibration while the implement is standing still.
5.
- Start calibration.
⇨
The following message appears:
"Hydraulics calibration ready"
6.
- Confirm within 3 seconds.
⇨
The following message appears:"Hydraulics calibration is running"
⇨
The drawbar now moves slowly to the left and then slowly to the right.
⇨
This procedure may last up to 20 seconds.
⇨
Calibration is completed when the message "Hydraulic calibration is running" is no longer
displayed.
7.
Come to a stop.
Configuring the speed sensor
The system must always know the current driving speed. To determine the driving speed, you can
use the following sensors:
▪ Wheel sensor - installed on the wheel of the trailed implement.
▪ Other sensors that transmit the speed signal through the ISOBUS.
Calibrating the wheel sensor
▪ Prior to initial start-up.
▪ After changing tires.
▪ When the speed shown on the work screen is incorrect.
▪ When the traveled distance shown on the work screen is incorrect.
6.4
6.4.1
When should you
calibrate?