Troubleshooting
Checking the version numbers
11
30283620-02-EN
V3.20151130_rev.2
51
1.
On the work screen, press:
>
> (
) >
⇨
The "
Diagnostic
" screen will appear.
⇨
On the screen, you can see the measured values and possible settings for the individual
functions.
Checking the version numbers
To check the version numbers, proceed as follows:
1.
On the work screen, press:
>
> (
) >
>
⇨
The "
Version number
" screen will appear.
⇨
All version numbers are displayed.
Version number
Meaning
Serial number
Serial number of the job computer
HW version
Hardware version of the job computer
SW (initial)
Delivered software version on the job computer
SW (current)
Current software version on the job computer
Pool version
Version of the pool with texts and images
Hydr. version
Version of the hydraulic system configuration
Alarm messages
Overview of the alarm messages
Alarm text
Possible cause
Remedial measure
Metering drive is stationary. The current speed of the metering drive is lower
than the minimum speed.
Stop immediately!
Remediate the cause.
The metering drive is
rotating too fast.
You are driving too fast. The metering drive
cannot work reliably at the current speed.
Drive more slowly or install a larger metering roll.
Metering drive cannot
maintain target rate.
You are driving too fast or too slow. It is not
possible to reach the target rate at the current
speed.
Drive more slowly or faster, so that the job
computer can control the target rate.
Metering drive regulation
The current speed of the metering drive is higher Drive more slowly or faster or install a larger
Procedure
11.2
Procedure
11.3