If a new software version is available for your on-board integrated display/controller, you can update
it.
You have received an update file in zip format from Müller-Elektronik.
1.
Unpack the zip file on an empty USB memory device.
2.
Insert the USB memory device into the on-board integrated display/controller.
⇨
The software automatically detects that a new software version is saved on the USB
memory device.
⇨
You will be asked whether you want to update the on-board integrated display/controller.
3.
Confirm.
⇨
The new software will be installed on the on-board integrated display/controller.
4.
Restart the on-board integrated display/controller.
10.4