T H E W O R L D P O W E R I N A N C H O R I N G S Y S T E M S
A
B
D
E
C
MAINTENANCE AND SERVICING
VFF 600 Free Fall Windlass
1.
Tools required
(i)
Muir clutch handle (P/N. F90-
HANNYL0600)
(ii)
Phillips Head screw driver
(iii)
Flat blade screw driver
(iv)
6mm (1/4") Allen key
(v)
3mm (1/8") Allen key
(vi)
3/16" Pin punch
(vii)
VFF 600 exploded view Dwg. K08-
FREVFF0600
2.
Removing clutch nut retaining washer
(P/N.
P21-304020.0007.005) & screw (P/N. S33-
30406.00012). Place Flat blade screwdriver (A)
into slot screw and then turn anti-clock wise to
remove.
3a.
Removing declutching pawl
(P/N. P13-
PWL303VFF600A). Place 3mm (1/8" ) Allen key
(B) into grub screw and then turn anti-clock
wise to release.
3b.
Removing 3/16" roll pin
(S93-PIN04.76025).
Place 4mm (3/16") pin punch into point (C)
and then tap carefully with a hammer to
remove.
4.
Removing chain cover
(P/N. P05-
CCV3160600FF). Place 6mm (1/4") Allen key
into (D) & (E) socket head cap screw (P/N.
S45-30406.35025) and then turn anti-clock wise
to remove. Now the chain cover can be
removed.
VR/VRC/VFF 600 12/01/2015
muir.com.au
12