background image

INSTALLATION INSTRUCTIONS

SENTRYX

 SOFTWARE ENABLED  

SUPER CENTURION

®

PRIOR-TO FIELD WORK

•  Access to the Sentryx website is required to complete this 

installation. If you do not have a user account or cannot log in, please 
contact your site administrator. [Alerts from the Sentryx platform 
will be provided for (a) coverage strength feedback in the "Field 
Work" section and (b) "success" in Section 36. In order to receive 
alerts, you need to create a Sentryx account (with current email 
address and cell number provided), select email and/or text alerts, 
and bring an electronic device to receive these alerts into the field.]

•  Before installation, visit each potential site and verify 4G LTE CAT 

M1 coverage. Reference the Mueller Cellular Signal Strength guide 
(F14334).   

FIELD WORK 

For Retrofit Kit

•  Signal Strength:

 

– Prior to disassembly of installed hydrant, confirm cell coverage at  

site of installation.

 

– Hold the new bonnet near the same height and location of 

installation.

 

– Place the commissioning tool close to the bonnet, approximately 

1/4˝ away, above ˝M˝ on the seal plate flange, while keeping away 
from iron parts. (Reference to the right ).

 

– Move the commissioning tool up along the curve of the bonnet 

keeping it approximately 1/4˝ away from the surface. This action 
will cause the bonnet to awaken and search for a connection.

 

ɥ If the bonnet does not establish a connection (i.e. no Sentryx 

alert is provided within 5 minutes), select a different location.

 

– Once a connection is established, the Sentryx platform will 

send out an email and/or text message (Depending on initial 
configuration) displaying the signal strength. See Appendix A.

 

ɥ If message indicates a weak signal, select a different location.

 

ɥ If message indicates a strong signal, proceed through 

instructions below. 

Note: Caution: Changes or modifications not expressly approved by Mueller Systems, LLC could void the user's authority to operate the equipment. This equipment has been tested and found to comply 

with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This 

equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, 

there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

 

– Reorient or relocate the receiving antenna.

 

– Increase the separation between the equipment and receiver.

 

– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

 

– Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,  

and (2) this device must accept any interference received, including interference that may cause undesired operation.

CAUTION

COMPLY WITH ALL REQUIRED INDUSTRY, SITE, STATE, AND 
FEDERAL SAFETY REQUIREMENTS
DO NOT DROP NEW HYDRANT LOWER STEM OR NEW 
BONNET ASSEMBLY. DAMAGE MAY OCCUR.
THE ANTENNA ON THE STEM CAN BE DAMAGED BY A 
FORCEFUL IMPACT FROM A SEAT WRENCH – UTILIZE CARE.
SENTRYX SOFTWARE ENABLED SUPER CENTURION  
IS DESIGNED TO WORK WITH MUELLER OEM PARTS ONLY.
AVOID BACKFILLING OVER EXPOSED BONNET AS DAMAGE 
TO PAINT MAY OCCUR

Summary of Contents for SENTRYX SUPER CENTURION

Page 1: ... proceed through instructions below Note Caution Changes or modifications not expressly approved by Mueller Systems LLC could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in...

Page 2: ...pletely 3 Open hydrant main valve completely 4 A continuous flow of water no matter how slight indicates hydrant is not properly isolated from the main water supply This issue must be corrected before any hydrant disassembly can proceed i e the water to the hydrant MUST be stopped EQUIPMENT TOOLSNEEDED PPE Hard hat Safety shoes Safety vest Safety glasses Work gloves Tool A 367 brass sleeve A 311 o...

Page 3: ... remove brass sleeve 6 Remove o ring from upper barrel Slide slotted end of A 359 over top of stem and engage the pin in upper stem Turn T head tightening wrench against stem 7 Pull up on seat wrench to be sure the main valve is completely closed The main valve must be closed or the upper valve plate will be damaged Lower support arm onto top flange of the upper barrel and tighten thumb screw to h...

Page 4: ...stainless steel lock washer 15 Clean inspect and replace any damaged parts Super Centurion main valve can be reversed to provide a new seal Replace drain valve facings if damaged 16 Reassemble main valve assembly to new lower stem Reverse steps with newly provided brass lower valve nut and tighten to 90 115 ft lbs 17 Assemble the new lower stem via the stem coupling to the upper stem ...

Page 5: ...to avoid cross threading 21 Reassemble wrench to upper stem Pull up on seat wrench to ensure main valve is completely closed lower support arm and tighten thumb screw while maintaining main valve in the closed position Turn main valve assembly clockwise to 100 190 ft lbs 22 Remove the seat wrench 23 Attach brass sleeve to upper stem and lubricate outside to protect o ring seals from thread damage ...

Page 6: ... the hold down nut and bonnet o ring 28 Take red plastic spacer and slide over bottom of hold down nut past the o ring and up against the hold down nut shoulder 29 Reassemble operating nut anti friction washer on top thrust collar of operating nut bonnet o ring hold down washer and hold down nut hand tighten to secure in place 30 Torque bonnet bolts 8 to 40 80 ft lbs 31 Torque hold down nut to 200...

Page 7: ...en drained below the antenna near the top of the lower stem Necessary for the stem to communicate with the bonnet d System water pressure is 20 psi or greater e Re swipe the commissioning tool If success feedback is not received within 5 minutes contact Customer Service Once a Sentryx software enabled Super Centurion has been successfully installed auto locating of hydrant using GPS will automatic...

Page 8: ... third parties Products above marked with a section symbol are subject to patents or patent applications For details visit www mwppat com These products are intended for use in potable water applications Please contact your Mueller Sales or Customer Service Representative concerning any other application s F 14286 10 20 FormoreinformationaboutMuellerortoviewourfulllineofwaterproducts pleasevisitww...

Reviews: