mu SPACE CORP Power Box 1200 User Manual Download Page 1

Power Box

Model 1200 v.2

User Manual

Summary of Contents for Power Box 1200

Page 1: ...Power Box Model 1200 v 2 User Manual...

Page 2: ...2...

Page 3: ...l Specifications 8 2 3 User Guide 9 2 4 Wiring Diagram 10 2 5 Mechanical Specifications 11 3 Installation 12 3 1 Installation Precautions 12 3 2 Installation Precautions 12 3 3 Wiring 13 4 Test Report...

Page 4: ...nergy storage system please make sure an energy storage battery is installed to ensure safe operation Please consult with your dealer before utilizing it as part of a device that could endanger person...

Page 5: ...this product in the following environments Places without air convection Places where there are flammable gasses corrosive substances or a large amount of dust Places of abnormally high or low temper...

Page 6: ...mpany for any questions Keep away from fire no heating No short circuit or reversed connecting No disassembling No hitting or impacting Improper operation may cause enormous loss Please be sure to ope...

Page 7: ...2 Product Overview 2 1 Device Overview 1 Negative terminal 2 Positive terminal 3 Case 7...

Page 8: ...e Current standard A 20 Charge Mode CCCV Discharge Discharge Cut off Voltage V 10V 1C 25C Maximum Continuous Discharge Current A 100 Maximum Discharge Current short pulsed A 100 Operating Temperature...

Page 9: ...2 3 User Guide Power box is connected to Load Supply via electrical wire Positive terminal is red nuts Negative terminal is blue nuts No reversed connecting 9...

Page 10: ...2 4 Wiring Diagram Wiring diagram of Power Box 10...

Page 11: ...2 5 Mechanical Specifications Power Box with side front and top views All unit in mm 11...

Page 12: ...l be noted when selecting the installation space for the Power Box Put the product in a ventilated place and ensure that the cooling holes and fan of the housing has a ventilation distance of more tha...

Page 13: ...nstallation engineer shall carry out the comprehensive selection in reference to relevant local standards Generally the length of a connecting cable is 2 10 m Too long cable will cause voltage drop re...

Page 14: ...4 2 Performance test The performance is the test charge and discharge at each C rate over discharge test 14...

Page 15: ...15...

Page 16: ...5 Equipment list No Description Quantity 1 Case 1 2 Battery cell 4 3 Battery management system BMS module 1 4 Busbar 3 5 Terminal 2 6 Electric wire 1 7 User manual 1 16...

Page 17: ...plied for use with the equipment specified Note that the plus and minus signs on the battery cell and on the equipment must ensure that it works properly Do not use any cell or battery that are not de...

Page 18: ...or completeness of the information provided within This document s information is updated and modified on a regular basis to reflect the current hardware and software status Additionally even if the...

Page 19: ...tional information on this product or encounter particular problems not covered in sufficient detail in the document Without mu Space s prior written consent no part of this publication may be copied...

Page 20: ...20...