4.2 20V4000L32FB engine data, tropical application (TA-Luft)
Explanation:
DL Reference value: Continuous power
BL Reference value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
Reference conditions
Engine model
20V 4000
L32FB
Application group
3A
Intake air temperature
°C
35
Charge-air coolant temperature
°C
53
Barometric pressure
mbar
1000
Site altitude above sea level
m
100
Table 23: Reference conditions
Power-related data (power ratings are net brake power as per ISO 3046)
Number of cylinders
20
Rated engine speed
A
rpm
1500
Mean piston speed
m/s
10.5
Continuous power as per ISO 3046
A
kW
2000
Mean effective pressure (pme) (continuous power ISO 3046)
bar
16.8
Table 24: Power-related data (power ratings are net brake power as per ISO 3046)
Site conditions (for max. power)
Number of cylinders
20
Relative humidity
A
%
60
Intake air temperature
A
°C
35
Intake air temperature, min.
L
°C
30
Intake air temperature, max.
L
°C
40
Mixture temperature after mixture cooler
A
°C
63
Ambient intake depression, max.
L
mbar
3
Pressure loss over air filter, max.
L
mbar
30
Exhaust back pressure, max.
L
mbar
60
Gas type: Biogas
X
Methane number, min.
L
120
Table 25: Site conditions (for max. power)
42 | Technical Data | MS150116/04E 2018-04
TIM-ID: 0000044675 - 003