8.16.5 Automatic oil filter – Cleaning
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Cleaner (Snow-White 11-0)
X00054118
1
Cleaner (Hakupur 50/136)
X00056700
1
WARNING
Compressed air gun ejects a jet of pressurized air.
Risk of injury to eyes and damage to hearing, risk of rupturing internal organs!
• Never direct air jet at people.
• Always wear safety goggles/face mask and ear defenders.
WARNING
Chemical substances in cleaners.
Risk of irritation and chemical burns!
• Always obey manufacturer's instructions for use.
WARNING
Cleaner is extremely caustic.
Risk of injury and suffocation!
• Avoid contact with eyes and skin.
• Do not inhale vapors and smoke.
• Do not eat, drink, smoke when working with cleaner.
• Wear protective clothing, gloves, and goggles / safety mask.
• Take measures against electrostatic charging.
NOTICE
Cleaning agents should not be left to take effect for too long.
Damage to components is possible!
• Observe manufacturer's instructions.
Automatic oil filter – Cleaning
1.
Carefully clean all components and connections.
• Clean all metallic parts with cleaner (Snow-White 11-0), then rinse with cleaner (Hakupur 50/136).
• Flush all oil ducts thoroughly with cleaner.
• Blow out all components thoroughly with compressed air.
2.
Wipe all sealing and mating faces dry with a clean, lint-free cloth.
3.
Inspect visually to ensure that all sealing and mating faces are clean. If not, repeat cleaning procedure.
4.
Remove corrosion inhibitor from new components with cleaner (Hakupur 50/136).
214 | Oil Filtration / Cooling | MS150123/01E 2017-05
TIM-ID: 0000014228 - 007