5.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑
Engine is stopped and starting disabled.
Putting into operation
Item
Task
Lube oil system
Check engine oil level (→ Page 211);
Preheat engine oil if required.
Coolant system
Check coolant level (→ Page 225).
Coolant system
Preheat coolant with preheating unit.
Fuel prefilter
Drain (→ Page 190);
Check that suction-side pressure indicated at the fuel prefilter pressure
gauge is within the limit (→ Page 189).
Engine control system
Refer to automation system operating instructions.
ECU
Check plug connections (→ Page 259).
EIM
Check plug connections (→ Page 261).
EMU
Check plug connections (→ Page 260).
MS15035/00E 2018-08
| Operation | 95
TIM-ID: 0000010655 - 004