8.1.4 Adhesive tape for SOLAS shielding – Application
Preconditions
☑
Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Adhesive tape
Applying adhesive tape – gener-
al information
Note:
Use the cable clamp to make a drainage
channel. This allows fluid to flow out without
pressure in case of leakage.
1.
Place cable clamp (3) on union.
2.
Affix adhesive tape (1) such that lettering (2)
faces out.
3.
Wrap adhesive tape without tensioning.
4.
Pull out cable clamp (3) after affixing adhe-
sive tape.
Sealing cone unions
Note:
For installation positions of sealing cone un-
ions, see (→ Page 148).
1.
Wrap three layers of adhesive tape from the
middle of the sealing cone union to area (A)
for at least 30 mm, ensuring that the adhe-
sive tape overlaps at least half its own width.
2.
Wrap three layers of adhesive tape from the
middle of the sealing cone union to area (B)
for at least 30 mm, ensuring that the adhe-
sive tape overlaps at least half its own width.
Plug-in connections
Note:
For installation positions of plug-in connections, see (→ Page 148).
1.
Apply adhesive tape flush.
2.
Apply three layers of adhesive tape such that at least 30 mm are covered from the middle of the screw to the
line.