Installing the 493.02 Chassis (FlexTest SE)
MTS 793 Controller Hardware
Installation
49
VMEbus Modules
The VMEbus compatible modules should be installed in chassis slots
according to the following guidelines.
•
The processor module is installed in slot 1
•
The I/O carrier module is installed in slot 2.
•
The System I/O module is installed in slots 4 and 5.
VMEbus Modules
S
LOT
M
ODULE
N
AME
F
UNCTION
Slot 1
Processor
Provides PIDF processing for the Controller and management
of the other plug-in modules in the standalone configuration.
Provides an interface between the Controller and an external
computer in the automated configuration.
Slot 2
Model 493. 40 I/O Carrier
Supports up to four mezzanine cards that can be used for
sensor conditioning, driving a servovalve, and in the
automated configuration, providing A/D and/or D/A channels.
Slot 3
Blank in standard
configurations.
May be used for additional
Model 493.40 I/O Carrier
(factory installed option for
automated systems)
Additional carrier chassis that can house up to four
mezzanine cards for expanded sensor conditioning and A/D
and D/A channels
Note
This is not a standard option. It is available only for
automated systems and must be configured at the
factory. For more information, contact MTS.
Slots 4, 5
Model 493.42 System I/O
Provides box-in and box-out connections for daisy chaining
multiple Controllers, analog and digital I/O, E-Stop, and HSM
and HPU control.
5
4
3
2
1
TYPE E PC-MIP
TYPE E PC-MIP
RUN 6TS BFL
ABT
RST
DEBUG
PCI MEZZANNE CARD
Placement of
VMEbus modules
in the chassis