background image

 

MTP 

Operating Manual 

Model MTP-1325 

Non-Contact Infrared Thermometers 

 

5

8

7p

9

12

11p

1

4

3p

6p

5p

9p

10p

 

MTP Instruments 

                                                                         

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for MTP-1325

Page 1: ...MTP Operating Manual Model MTP 1325 Non Contact Infrared Thermometers 5 8 7p 9 12 11p 1 4 3p 6p 5p 9p 10p MTP Instruments www com information itm com 1 800 561 8187...

Page 2: ...ON 3 FEATURES 3 WIDERANGEAPPLICATION 3 SAFETY 4 DISTANCE SPOTSIZE 4 SPECIFICATIONS 5 FRONTPANELDESCRIPTION 6 INDICATOR 6 MEASURMENTOPERATION 7 BATTERYREPLACEMENT 8 NOTES 8 MAINTENANCE 11 www com infor...

Page 3: ...such as moving object the surface with electricity current or the objects which are uneasy to be touched Proper use and care of this meter will provide years of reliable service FEATURES Rapid detecti...

Page 4: ...the laser light beam impinge on any gas which can explode Distance Spot Size As the distance D from the object increases the spot size S of the area measured by the unit becomes larger The relationsh...

Page 5: ...F 0 5 or 0 5 C 0 9 F Response time 150ms Spectral response 8 14um Emissivity Fixed at 0 95 Over range indication LCD will show Polarity Automatic no indication for positive polarity Minus sign for ne...

Page 6: ...target is at least twice as large as the spot size 2 FRONT PANEL DESCRIPTION IR sensor LCD Display Laser pointer beam Measurement Trigger Battery Cover Handle Grip 3 INDICATOR Data hold Laser on symb...

Page 7: ...battery if the display does not light Release the Trigger and the HOLD display icon will appear on the LCD indicating that the reading is being held The meter will automatically power down after appro...

Page 8: ...ut the battery from instrument and replace with a new 9 Volt battery and place the battery cover back 6 NOTES How it Works Infrared thermometers measure the surface temperature of an object The unit s...

Page 9: ...ate hot spot Reminders Not recommended for use in measuring shiny or polished metal surfaces stainless steel aluminum etc See Emissivity The unit cannot measure through transparent surfaces such as gl...

Page 10: ...Cloth black 0 98 Concrete 0 94 Human skin 0 98 Cement 0 96 Lather 0 75 to 0 80 Sand 0 90 Charcoal powder 0 96 Earth 0 92 to 0 96 Lacquer 0 80 to 0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to...

Page 11: ...manual and should only be carried out by qualified trained technician Periodically wipe the body with a dry cloth Do not use abrasives or solvents on this instrument For service use only manufacturer...

Page 12: ...ge Social 4409 rue Charleroi Montr al Nord Qu bec H1H 1T6 T l phone 514 326 7167 T l copieur 514 326 7835 Ligne directe 1 888 326 7167 Site Web www mtpinc com Courrier lectronique info mtpinc com www...