4
2.2.2 AC Voltage
Range
Accuracy
Resolution
60.00mV
± ( 1.2%+3 )
0.01mV
600.0mV
0.1mV
6.000V
± ( 0.8%+3 )
1mV
60.00V
10mV
600.0V
100mV
600V
± ( 1.2%+3 )
1V
AC True RMS
Frequency: 40Hz
~
1kHz
Overload protection: 600V DC or AC rms
Impedance: 10M
Ω
,
More than 100M
Ω
on 60mV/600mV range
2.2.3 DC Current
Range
Accuracy
Resolution
600
µ
A
± ( 1.2%+2 )
0.1
µ
A
6000
µ
A
1
µ
A
60mA
10
µ
A
600mA
100
µ
A
6A
± ( 2.0%+3 )
1mA
15A
10mA
Overload protection: 0.8A/600V, 15A/600V fuse
Continuous testing the maximum steady-state current of 1A
2.2.4 AC Current
Range
Accuracy
Resolution
600
µ
A
± ( 1.5%+3 )
0.1
µ
A
6000
µ
A
1
µ
A
60mA
10
µ
A
600mA
100
µ
A
6A
± ( 2.5%+5 )
1mA
15A
10mA
AC True RMS
Frequency: 40Hz
~
1kHz
Overload protection: 0.8A/600V, 15A/600V fuse
Continuous testing the maximum steady-state current of 1A
2.2.5 Resistance
Range
Accuracy
Resolution
600
Ω
± ( 1.0%+3 )
0.1
Ω
6k
Ω
± ( 1.0%+2 )
1
Ω
60k
Ω
10
Ω
600k
Ω
100
Ω
6M
Ω
1k
Ω
60M
Ω
± (1.5%+3 )
10k
Ω
Overload protection: 600V DC or AC rms