Summary of Contents for columbia aqua FC-750-SOBREMESA-F

Page 1: ...Technical Manual Service Booklet MT FC 750 SOBREMESA RO FC 750 SOBREMESA ROP FC 750 SOBREMESA F FC 750 SOBREMESA UF ...

Page 2: ......

Page 3: ...T WATER FROM YOUR DISPENSER 4 IDENTIFYING THE MANAGEMENT AND CONTROL COMPONENTS 5 USER INTERFACE 6 HOW TO ACCESS THE FILTERS 7 WARRANTY 8 RECORDING SHEET FOR THE INSTALLATION AND STARTING UP OF THE EQUIPMENT TECHNICIAN 9 SERVICE BOOKLET USER 10 NOTES 4 6 11 11 12 13 14 15 16 18 ...

Page 4: ...caliente AMBIENT Producción de agua a temperatura ambiente Desconectando la caliente LED Sistema de información multifunción mediante LED ANTIBACTERIA Protector para la salida de los grifos fabricado en plástico antibacteriano Extraíble y lavable Ease of access and maintenance Exclusive filters Maximum hygiene and security Membrane Installed Maximum hygiene Post filter that adjusts the pH Rapid an...

Page 5: ...horro de energía Un sensor de luminosidad deja parte de la fuente en stand by durante la noche pa ra reducir el consumo eléctrico Top table equipment ideal for small offices Energy saving system A brightness sensor leaves part of the fountain in stand by during the night to reduce power consumption ...

Page 6: ...at have a diameter larger than 5 microns The carbon filter reduces the flavour and smell of the water as well as its organic components Based on the characteristics of the water to be treated UF Model This equipment comprises a first Filtration stage The treatment of water through Ultrafiltration is able to retain suspended parti cles that have a diameter between 0 1 and 0 0001 microns Based on th...

Page 7: ...rature Control Overheating Protection HYDRAULIC SCHEME RO MODEL IN ENTRADA IN ENTRADA OUT R OUT SALIDA OUT RO A x B x C 493 x 260 x 460 19 kg 4 liters It is reduced to 3 2 liters once a floating valve is incorporated 1 5 liters 220 240 Vac 1 11 CV sealed 120 W Capillary type R134A Capillary Thermostat Band Heater 430 W Bi metal auto buildable Bi metal auto buildable A C B MEMBRANA RO ELECTROVÁLVUL...

Page 8: ...D GAC LLAVE DE PASO RESTRICTOR RECHAZO MEMBRANA RO VÁLVULA FLOTADOR INTERRUPTOR NIVEL POST FILTRO REMINERALIZADOR BOMBA DEPÓSITO SUPERIOR SEGUN MODELO A B C PUMP SHUT OFF VALVE SHUT OFF VALVE SHUT OFF VALVE REJECTION RESTRICTOR INLET SOLENOID VALVE FLOAT VALVE FLOAT VALVE FLOAT VALVE UPPER RESERVOIR UPPER RESERVOIR UPPER RESERVOIR LEVEL SWITCH DEPENDING ON THE MODEL SEDIMENT PRE FILTER CARBON GAS ...

Page 9: ...9 ELECTRIC SCHEME RO AND ROP MODELS ELECTRIC SCHEME UF AND F MODELS ...

Page 10: ...10 RO ROP MODELS HYDRAULIC CONNECTION SCHEME U UF MODELS HYDRAULIC CONNECTION SCHEME INLET DRAIN INLET ...

Page 11: ...tor this equipment includes a brightness sensor When saving mode is activated the equipment will disconnect the heating system during the evening when the surroundings of the equipment are dark To deactivate the saving mode press the 1 2 HOT WARM button for 5 seconds Dispensing nozzle this can be disconnected to be cleaned periodically Dispensing lever press this button to extract cold wa ter or h...

Page 12: ... energy saving system is activated which allows the equipment to work at full capacity while its su rroundings are illuminated and once it is dark at night it switches the equipment to energy saving mode by deacti vating the water heating system image 4 The red light below the HOT WARM button indicates that the rear switch of the equipment HOT is in the ON po sition and therefore the heating syste...

Page 13: ...13 ...

Page 14: ...ent of the quality of the water to be treated based on the charac teristics of the equipment and all applicable laws The installer and or distributor guarantees the correct installation and imple mentation of the equipment as indicated by the manufacturer and applicable law and will also respond for any lack of conformity that may result from the incorrect application instalment or implementation ...

Page 15: ...tados para ello Lavado postfiltro de carbón Lavado de filtro de carbón 18 RECORD SHEET FOR THE INSTALLATION AND COMMISSIONING OF THE EQUIPMENT TECHNICIAN Serial number Date and Signature NOTES FOR THE TECHNICIAN INSTALLER Read this Manual carefully If you have any doubts get in touch with the Technical Assistance Service T A S of your distributor The data market with must be filled by the installi...

Page 16: ...GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELLO DATE TYPE OF SERVICE NAME SIGNATURE AND SEAL OF THE AUTHORIZED TECHNICIAN SET UP FULL MAINTENANCE REPARATION SANITIZATION OTHER TECHNICIAN SEAL ORDINARY EXTRAORDINARY WARRANTY FULL MAINTENANCE FULL MAINTENANCE FULL MAINTENANCE FULL MAINTENAN...

Page 17: ... ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELLO TÉCNICO ORDINARIA EXTRAORDINARIA GARANTÍA SELLO DATE TYPE OF SERVICE NAME SIGNATURE AND SEAL OF THE AUTHORIZED TECHNICIAN SET UP FULL MAINTENANCE FULL MAINTENANCE FULL MAINTENANCE FULL MAINTENANCE FULL MAINTENANCE FULL MAINTENANCE REPARATION REPARATION REPARATION REPARATION REPARATION REPARATION SANITIZATION S...

Page 18: ...18 10 NOTES ...

Page 19: ...19 10 NOTES ...