The original operation manual is in German. Other
language versions are translations from German.
USER MANUAL
SAFETY INSTRUCTIONS
General safety information for the use of electrical devices:
To avoid injury from fire or electric shock, please ensure
compliance with the safety instructions when using this
device. Please read the instructions carefully and make sure
that you have understood them well. Keep the manual near
the equipment to be able to read it at any time. Always use
current sources that are connected to the ground and
provide the necessary voltage (indicated on the label
on the device). If you have any doubts, let an electrician
check if your outlet is properly grounded. Never use
a damaged power cable. Do not open the unit in damp or
wet environments, or if your hands or body are damp or
wet. Protect the unit from solar radiation. Use the device in
a protected location to avoid damaging the equipment or
endangering others. Make sure the device is able to cool
and avoid placing it too close to other devices that produce
heat. Before cleaning, disconnect it from the power source.
Use a soft damp cloth for cleaning. Avoid using detergents
and make sure that no liquid enters the unit. No internal
element of this device needs to be maintained by the user.
Opening the device without our approval leads to a loss
of warranty!
SAFETY GUIDELINES
1 Please carefully read and understand these
instructions before operating the device! Please
observe the safety guidelines carefully in order to
prevent damages through improper use!
2. Please keep this manual available for future
reference. If this device is passed on to third parties,
the manual must be passed on with it.
3.
Only use this device indoors and for its intended use.
4.
We do not offer any warranty for damages resulting
from improper use or incorrect operation.
5.
Before the first use, please check whether the main
voltage type and current comply with the indicated
data on the type plate.
6.
This device is not intended to be used by persons
(including children) with limited physical, sensory
or mental aptitudes or with a lack of experience
and/or knowledge, unless they are supervised by
a person responsible for their safety or have received
instruction from this person as to how the device is
used.
7.
ELECTRIC SHOCK HAZARD! Do not attempt to repair
the unit yourself. In case of device failure, repairs
must be done by qualified experts.
The operation manual must be read carefully.
Satisfies applicable safety standards.
Never dispose of electrical equipment together
with household waste.
Attention! Risk of electric shock!
Attention! The device mechanism may inflict
serious injury or cause death.
PLEASE NOTE!
Drawings in this manual are for
illustration purposes only and in some details they
may differ from the actual machine.
8. Please check the main plug and power cable
regularly. If the power cable for this device is
damaged, it has to be replaced by the manufacturer
or its customer service or another qualified person in
order to prevent hazards.
9.
Prevent damages to the power cable by avoiding
squeezing or bending it or rubbing it on sharp
edges. Also keep the power cable away from hot
surfaces and open flames.
10. ATTENTION! DANGER TO LIFE! While cleaning, never
immerse the device in water or other liquids.
11. Under no circumstances should the housing be
opened.
12. It is forbidden to use the device if damaged or
defective.
TECHNICAL DATA
Product name
Submersible pump
Model
MSW
-SPP
44
-075
MSW
-SPP
44
-037
MSW
-SPP
32
-075
MSW
-SPP
48
-110
MSW
-SPP
48
-220
Voltage [V~]/
Frequency
[Hz]
230/50
Rated power
[kW/HP]
0,75/
1
0,37/
0,5
0,75/
1
1,1/
1,5
2,2/
3
Rated Current
[A]
5
3
5
6
14
Protection
class
I
IP protection
class
IP68
Insulation
class
B
Working
mode
S1
Motor rota-
tional speed
[rpm]
2850
Number of
stages
(impellers)
10
6
24
8
14
Borewell di-
ameter [mm]
95
95
75
95
95
Water con-
nector stub
diameter
1,25’’ 1,25’’ 1,25’’
2’’
2’’
Max. head
lift [m]
72
43
85
54
96
Max. water
flow [m
3
/h]
6
6
3,8
10,8
10,8
Max. sand
content in
water [%]
0,25
Pumped
water max.
temp. [°C]
35
Max. number
of starts/h
50
Length of
power cable
[m]
20 ± 1
Dimensions
[mm]
φ
90
x870
φ
95
x725
φ
75
x1290
φ
95
x920
φ
95
x1362
Weight [kg]
16,9
10
15,4
16
21,9
Product
name
Submersible pump
Model
MSW
-SPP
32
-055
MSW
-SPP
44
-055
MSW
-SPP
32
-037
MSW
-SPP
32
-025
MSW
-SPP
43
-075
Voltage [V~]/
Frequency
[Hz]
230/50
Rated power
[kW/HP]
0,55/
0,75
0,55/
0,75
0,37/
0,5
0,25/
0,33
0,75/
1
Rated
Current [A]
4
4
3
2,5
5
Protection
class
I
IP protection
class
IP68
Insulation
class
B
Working
mode
S1
Motor rota-
tional speed
[rpm]
2850
Number of
stages
(impellers)
17
8
11
8
12
Borewell
diameter
[mm]
75
95
75
75
95
Water con-
nector stub
diameter
1,25’’ 1,25’’
1,25’’
1,25’’ 1,25’’
Max. head
lift [m]
60
58
39
28
91
Max. water
flow [m
3
/h]
3,8
6
3,8
3,8
4,8
Max. sand
content in
water [%]
0,25
Pumped
water max.
temp. [°C]
35
Max. number
of starts/h
50
Length of
power cable
[m]
20 ± 1
Dimensions
[mm]
φ75
x1035
φ95
x792
φ75
x841
φ75
x711
φ95
x893
Weight [kg]
12,7
12,8
10
9,5
16,5
MSW
-SPP
44
-075
Head lift [m]
72 69
67
65
62
58
water
flow
m
3
/h
0
0,6 1,2 1,8 2,4 3,0
l/
min
0
10
20
30
40
50
MSW
-SPP
44
-075
Head lift [m]
53
46
37
27
16
water
flow
m
3
/h 3,6 4,2 4,8 5,4 6,0
l/
min
60
70
80
90 100
MSW
-SPP
44
-037
Head lift [m]
43 42
40
39
37
35
water
flow
m
3
/h
0
0,6 1,2 1,8 2,4 3,0
l/
min
0
10
20
30
40
50
MSW
-SPP
44
-037
Head lift [m]
32
27
22
16
9
water
flow
m
3
/h 3,6 4,2 4,8 5,4 6,0
l/
min
60
70
80
90 100
Head lift and water flow
MSW
-SPP
32
-075
Head lift [m]
85 82
79
74
70
water
flow
m
3
/h
0
0,5 1,0 1,5 1,8
l/
min
0
8
17
25
30
MSW
-SPP
32
-075
Head lift [m]
65
52
33
3
water
flow
m
3
/h 2,0 2,5 3,0 3,8
l/
min
33
42
50
63
U S E R M A N U A L
9
Rev. 09.02.2018
8
Rev. 09.02.2018
MSW
-SPP
48
-110
Head lift [m]
54
52
51
48
45
water
flow
m
3
/h
0
1,2
2,4
3,6
4,8
l/
min
0
20
40
60
80
MSW
-SPP
48
-110
Head lift [m]
43
37
32
22
12
water
flow
m
3
/h
6,0
7,2
8,4
9,6
10,8
l/
min
100
120 140 160
180